MD 100 Cooling Water
Precise water control with proven and compact measuring system
- High-precision optics
- High accuracy and reproducibility through precision interference filter (5 nm)
- Industry specific parameter combinations available
Scale, corrosion, deposits and damage due to micro-organisms (biofilms) are just some of the factors which can seriously impair cooling water systems. Proper management of the water in a cooling system will usually result in a considerable improvement in water quality and thus drastically reduced operating costs and long-term prevention of downtimes.
The Colorimeter MD 100 Cooling Water is just the right system for this purpose. It tests your water parameters quickly, easily and precisely.
The Colorimeter MD 100 Cooling Water is just the right system for this purpose. It tests your water parameters quickly, easily and precisely.
Part Number 276240
Applications
- Boiler Water
- Cooling Water
- Disinfection Control
- Drinking Water Treatment
- Galvanization
- Pool Water Control
- Raw Water Treatment
- Waste Water Treatment
Product information
The MD 100 has several key features that make it a favorite among users.
-
Waterproof Design
The IP 68 design of this instrument ensures that the MD 100 remains water tight for up to 1 hour at 0.1 meter.
Don't worry about dropping the instrument into a body of water - it floats! -
Accurate, Reproducible Results
The optical system of the MD 100 utilizes LEDs and interference filters
which quickly gives you results that you can be confident in. You always measure in the spectral peak. -
User Calibration Mode
A one-point calibration is possible.
Additionally, all MD 100 instruments have the ability to display readings directly in ABS or %T units. -
One-time-Zero Function
Don't waste time waiting for your instrument to Zero after each test.
When testing a new sample, zero the instrument once and all subsequent tests of that sample do not require you to re-zero the instrument. -
Automatic Data Storage with Transfer Capabilities
The MD 100 automatically stores the last 16 readings with time and date stamp.
These results can be transferred to a spreadsheet using the IRiM accessory. -
Ergonomic Design
Whether you're using the MD 100 out in the field or in the lab, the design of the instrument makes it easy to handle and view the display.
If you're using the instrument in the lab, the rubber feet on the bottom of the housing eliminates the need for two hand operation or to chase your instrument around the workbench. -
Factory Programmed
All MD 100 instruments are supplied ready to use with up to 14 calibration curves.
All you need to do is select the test you need, prepare your sample and test! -
Scroll Driven Menu System
The simple interface allows you to quickly reach the test you need.
When the instrument is turned on, it will automatically display the last test used. - 2-Year Warranty
Optics | LEDs, interference filters (IF) and photo sensor in transparent sample chamber. Depending on the version, up to 3 different interference filters are used. Wavelength specifications of interference filters: 430 nm Δλ = 5 nm 530 nm Δλ = 5 nm 560 nm Δλ = 5 nm 580 nm Δλ = 5 nm 610 nm Δλ = 6 nm 660 nm Δλ = 5 nm |
Wavelength Accuracy | ± 1 |
Photometric Range | -2500 - 2500 mAbs |
Photometric Accuracy | 3 % FS (T = 20 °C – 25 °C) |
Display | backlit LCD (on keypress) |
Interfaces | Infrared |
Operation | Foil keypad |
Auto – OFF | Yes |
Calibration | factory calibration and user calibration. Reset to factory calibration possible |
Internal Storage | internal ring memory for 16 data sets |
Power Supply | 4 micro batteries (AAA) |
Battery Life Time | approx. 17 hours |
Clock | Real Time Clock and Date |
Portability | Portable |
Environmental Conditions | Temperature: 5 - 40 °C rel. humidity: 30 - 90 % (non condensing) |
Protection Class | IP 68 |
Compliance | CE |
Dimensions | 155 x 75 x 35 mm |
Weight | 260 g |
Testparameter | Measuring Range | Method No. | Chemical Method |
---|---|---|---|
Aluminium PP | 0.01 - 0.25 mg/L Al | M50 | Eriochrom Cyanine R |
Bromine T | 0.05 - 13 mg/L Br2 | M80 | DPD |
Chlorine dioxide T | 0.02 - 11 mg/L ClO2 | M120 | DPD / Glycine |
Chlorine HR (KI) T |
5 - 200 mg/L Cl2 | M105 | KI / Acid |
Chlorine L | 0.02 - 4.0 mg/L Cl2 | M101 | DPD |
Chlorine T | 0.01 - 6.0 mg/L Cl2 | M100 | DPD |
Copper T | 0.05 - 5 mg/L Cu | M150 | Biquinoline |
Iron in Mo PP (224) | 0.01 - 1.8 mg/L Fe | M224 | TPTZ |
Iron LR L (A) | 0.03 - 2 mg/L Fe | M225 | Ferrozine / Thioglycolate |
Molybdate HR L | 1 - 100 mg/L MoO4 | M254 | Thioglycolate |
Molybdate LR PP | 0.03 - 3 mg/L Mo | M251 | Ternary Complex |
Ozone T | 0.02 - 2 mg/L O3 | M300 | DPD / Glycine |
Polyacrylate L | 1 - 30 mg/L Polyacryl | M338 | Turbidity |
Sulphate PP | 5 - 100 mg/L SO4 2- | M360 | Bariumsulphate Turbidity |
Triazole PP | 1 - 16 mg/L Benzotriazole or Tolyltriazole | M388 | Catalyzed UV Digestion |
Zinc L | 0.1 - 2.5 mg/L Zn | M405 | Zincon / EDTA |
Title | Measuring Range | Chemical Method | Packaging Unit | Part Number | Add to quotation cart |
---|---|---|---|---|---|
VARIO Aluminium Reagent, Set F20 | 0.01 - 0.25 mg/L Al | Eriochrom Cyanine R | 1 pc. | 535000 |
|
DPD No.1 | 0.05 - 13 mg/L Br2 | DPD | Tablet / 100 | 511050BT |
|
DPD No. 1 | 0.05 - 13 mg/L Br2 | DPD | Tablet / 250 | 511051BT |
|
DPD No. 1 | 0.05 - 13 mg/L Br2 | DPD | Tablet / 500 | 511052BT |
|
DPD No. 1 High Calcium | 0.05 - 13 mg/L Br2 | DPD | Tablet / 100 | 515740BT |
|
DPD No. 1 High Calcium | 0.05 - 13 mg/L Br2 | DPD | Tablet / 250 | 515741BT |
|
DPD No. 1 High Calcium | 0.05 - 13 mg/L Br2 | DPD | Tablet / 500 | 515742BT |
|
DPD No. 3 | 0.01 - 6.0 mg/L Cl2 a) | DPD | Tablet / 100 | 511080BT |
|
DPD No. 3 | 0.01 - 6.0 mg/L Cl2 a) | DPD | Tablet / 250 | 511081BT |
|
DPD No. 3 | 0.01 - 6.0 mg/L Cl2 a) | DPD | Tablet / 500 | 511082BT |
|
DPD No. 3 High Calcium | 0.01 - 6.0 mg/L Cl2 a) | DPD | Tablet / 100 | 515730BT |
|
DPD No. 3 High Calcium | 0.01 - 6.0 mg/L Cl2 a) | DPD | Tablet / 250 | 515731BT |
|
DPD No. 3 High Calcium | 0.01 - 6.0 mg/L Cl2 a) | DPD | Tablet / 500 | 515732BT |
|
DPD No. 4 | 0.01 - 6.0 mg/L Cl2 a) | DPD | Tablet / 100 | 511220BT |
|
DPD No. 4 | 0.01 - 6.0 mg/L Cl2 a) | DPD | Tablet / 250 | 511221BT |
|
DPD No. 4 | 0.01 - 6.0 mg/L Cl2 a) | DPD | Tablet / 500 | 511222BT |
|
DPD No. 3 Evo | 0.01 - 6.0 mg/L Cl2 a) | DPD | Tablet / 100 | 511420BT |
|
DPD No. 3 Evo | 0.01 - 6.0 mg/L Cl2 a) | DPD | Tablet / 250 | 511421BT |
|
DPD No. 3 Evo | 0.01 - 6.0 mg/L Cl2 a) | DPD | Tablet / 500 | 511422BT |
|
DPD No. 4 Evo | 0.01 - 6.0 mg/L Cl2 a) | DPD | Tablet / 100 | 511970BT |
|
DPD No. 4 Evo | 0.01 - 6.0 mg/L Cl2 a) | DPD | Tablet / 250 | 511971BT |
|
DPD No. 4 Evo | 0.01 - 6.0 mg/L Cl2 a) | DPD | Tablet / 500 | 511972BT |
|
DPD 1 Buffer Solution, Blue Bottle | 0.02 - 4.0 mg/L Cl2 a) | DPD | 15 mL | 471010 |
|
DPD 1 Buffer Solution | 0.02 - 4.0 mg/L Cl2 a) | DPD | 100 mL | 471011 |
|
DPD 1 Buffer Solution | 0.02 - 4.0 mg/L Cl2 a) | DPD | 1 pc. | 471016 |
|
DPD 1 Reagent Solution, Green Bottle | 0.02 - 4.0 mg/L Cl2 a) | DPD | 15 mL | 471020 |
|
DPD 1 Reagent Solution | 0.02 - 4.0 mg/L Cl2 a) | DPD | 100 mL | 471021 |
|
DPD 1 Reagent Solution | 0.02 - 4.0 mg/L Cl2 a) | DPD | 1 pc. | 471026 |
|
DPD 3 Solution, Red Bottle | 0.02 - 4.0 mg/L Cl2 a) | DPD | 15 mL | 471030 |
|
DPD 3 Solution | 0.02 - 4.0 mg/L Cl2 a) | DPD | 100 mL | 471031 |
|
DPD 3 Solution | 0.02 - 4.0 mg/L Cl2 a) | DPD | 1 pc. | 471036 |
|
DPD Reagent Set | 0.02 - 4.0 mg/L Cl2 a) | DPD | 1 pc. | 471056 |
|
Chlorine HR (KI) | 5 - 200 mg/L Cl2 | KI / Acid | Tablet / 100 | 513000BT |
|
Chlorine HR (KI) | 5 - 200 mg/L Cl2 | KI / Acid | Tablet / 250 | 513001BT |
|
Acidifying GP | 5 - 200 mg/L Cl2 | KI / Acid | Tablet / 100 | 515480BT |
|
Acidifying GP | 5 - 200 mg/L Cl2 | KI / Acid | Tablet / 250 | 515481BT |
|
Set Chlorine HR (KI)/Acidifying GP 100 Pc. | 5 - 200 mg/L Cl2 | KI / Acid | 100 each | 517721BT |
|
Set Chlorine HR (KI)/Acidifying GP 250 Pc. | 5 - 200 mg/L Cl2 | KI / Acid | 250 each | 517722BT |
|
Chlorine HR (KI) | 5 - 200 mg/L Cl2 | KI / Acid | Tablet / 100 | 501210 |
|
Chlorine HR (KI) | 5 - 200 mg/L Cl2 | KI / Acid | Tablet / 250 | 501211 |
|
Glycine | 0.02 - 11 mg/L ClO2 | DPD / Glycine | Tablet / 100 | 512170BT |
|
Glycine | 0.02 - 11 mg/L ClO2 | DPD / Glycine | Tablet / 250 | 512171BT |
|
Set DPD No. 1/No. 3 100 Pc. | 0.02 - 11 mg/L ClO2 | DPD / Glycine | 100 each | 517711BT |
|
Set DPD No. 1/No. 3 250 Pc. | 0.02 - 11 mg/L ClO2 | DPD / Glycine | 250 each | 517712BT |
|
Set DPD No. 1/Glycine 100 Stck. | 0.02 - 11 mg/L ClO2 | DPD / Glycine | 100 each | 517731BT |
|
Set DPD No. 1/Glycine 250 Stck. | 0.02 - 11 mg/L ClO2 | DPD / Glycine | 250 each | 517732BT |
|
Set DPD No. 1/No. 3 High Calcium 100 Pc. | 0.02 - 11 mg/L ClO2 | DPD / Glycine | 100 each | 517781BT |
|
Set DPD No. 1/No. 3 High Calcium 250 Pc. | 0.02 - 11 mg/L ClO2 | DPD / Glycine | 250 each | 517782BT |
|
Copper No. 1 | 0.05 - 5 mg/L Cua) | Biquinoline | Tablet / 100 | 513550BT |
|
Copper No. 1 | 0.05 - 5 mg/L Cua) | Biquinoline | Tablet / 250 | 513551BT |
|
Copper No. 2 | 0.05 - 5 mg/L Cua) | Biquinoline | Tablet / 100 | 513560BT |
|
Copper No. 2 | 0.05 - 5 mg/L Cua) | Biquinoline | Tablet / 250 | 513561BT |
|
Set Copper No. 1/No. 2 100 Pc. | 0.05 - 5 mg/L Cua) | Biquinoline | 100 each | 517691BT |
|
Set Copper No. 1/No. 2 250 Pc. | 0.05 - 5 mg/L Cua) | Biquinoline | 250 each | 517692BT |
|
ValidCheck Copper 2 mg/l | 0.05 - 5 mg/L Cua) | Biquinoline | 1 pc. | 48141525 |
|
VARIO Fe in MO Reagent Set | 0.01 - 1.8 mg/L Fe | TPTZ | 1 Set | 536010 |
|
Acidity / Alkalinity P Indicator PA1 | 0.03 - 2 mg/L Fe | Ferrozine / Thioglycolate | 65 mL | 56L013565 |
|
Hardness Calcium Buffer CH2 | 0.03 - 2 mg/L Fe | Ferrozine / Thioglycolate | 65 mL | 56L014465 |
|
KP962-Ammonium Persulphate Powder | 0.03 - 2 mg/L Fe | Ferrozine / Thioglycolate | Powder / 40 g | 56P096240 |
|
KS63-FE6-Thioglycolate/Molybdate HR RGT | 0.03 - 2 mg/L Fe | Ferrozine / Thioglycolate | 30 mL | 56L006330 |
|
Iron Reagent FE6 | 0.03 - 2 mg/L Fe | Ferrozine / Thioglycolate | 65 mL | 56L006365 |
|
Iron Reagent FE5 | 0.03 - 2 mg/L Fe | Ferrozine / Thioglycolate | 65 mL | 56L006165 |
|
VARIO Molybdenum LR, Set F10 | 0.03 - 3 mg/L Mo | Ternary Complex | 1 pc. | 535450 |
|
KS173-P2-2,4 Dinitrophenol Indicator | 1 - 30 mg/L Polyacryl | Turbidity | 65 mL | 56L017365 |
|
Polyacrylate L Reagent Set | 1 - 30 mg/L Polyacryl | Turbidity | 1 pc. | 56R019165 |
|
KS336-Propan-2-ol, 65 mL | 1 - 30 mg/L Polyacryl | Turbidity | 65 mL | 56L033665 |
|
VARIO Sulfa 4 F10 | 5 - 100 mg/L SO4 2- | Bariumsulphate Turbidity | Powder / 100 pc. | 532160 |
|
ValidCheck Sulfat 75 mg/l | 5 - 100 mg/L SO4 2- | Bariumsulphate Turbidity | 1 pc. | 48311325 |
|
VARIO Triazole Rgt Powder Pack F25 | 1 - 16 mg/L Benzotriazole or Tolyltriazole | Catalyzed UV Digestion | Powder / 100 pc. | 532200 |
|
Vario Rochelle Salt Solution, 30 ml | 1 - 16 mg/L Benzotriazole or Tolyltriazole | Catalyzed UV Digestion | 30 mL | 530640 |
|
KS 89 - Cationic Suppressor | 0.1 - 2.5 mg/L Zn | Zincon / EDTA | 65 mL | 56L008965 |
|
Zinc LR Reagent Set | 0.1 - 2.5 mg/L Zn | Zincon / EDTA | 1 pc. | 56R023965 |
|
Zinc Buffer Z1B | 0.1 - 2.5 mg/L Zn | Zincon / EDTA | 65 mL | 56L024365 |
|
Zinc Indicator Z4P | 0.1 - 2.5 mg/L Zn | Zincon / EDTA | Powder / 20 g | 56P024420 |
|
- Instrument in plastic case
- Adapter for ø 16 mm cuvettes
- 4 micro batteries (AAA)
- 3 round cuvettes (glass) with lid
- 3 round cuvettes ø 16 mm (glass) with lid
- Sealing rings
- Stirring rod
- Brush
- Syringe (20 ml)
- Measuring Beaker (100 ml)
- Instruction manual
- Quick Start Guide
- Certificate (COC)
- Warranty information