MD 200 Ozone, tablet reagents
Precise results using high-quality interference filters
- Scroll memory
- Automatic switch-off
- Real-Time-Clock and date
- Calibration mode indicator
Versatile, compact and: The benchtop photometer MD 200 combines high-quality interference filters with long-term stable LEDs as light sources in a high-precision optic. The result: precise measurement results at all times - no matter where you use it.
Part Number 2899802
Applications
- Boiler Water
- Disinfection Control
- Drinking Water Treatment
- Raw Water Treatment
- Waste Water Treatment
Product information
-
Versatile use
The MD 200 photometer can be used in almost all areas of water analysis. -
Precise and low maintenance
The high-precision optics, which in addition to long-term stable LEDs as light sources, also offer high-quality interference filters, ensure precise and reproducible measurement results. In addition, these components make the photometer low-maintenance. -
User friendly
The devices impress with their ease of use, ergonomic design and compact dimensions, which makes handling the devices easy and safe. -
Reagents
Use long-term stable Lovibond® reagent tablets (5-10 years guaranteed minimum durability) or Lovibond® liquid reagents.
Optics | LEDs, interference filters (IF) and photo sensor in transparent sample chamber. Depending on the version, up to 3 different interference filters are used. Wavelength specifications of interference filters: 430 nm Δλ = 5 nm 530 nm Δλ = 5 nm 560 nm Δλ = 5 nm 610 nm Δλ = 6 nm |
Wavelength Accuracy | ± 1 nm |
Photometric Range | -2500 - 2500 mAbs |
Photometric Accuracy | 3 % FS (T = 20 °C – 25 °C) |
Display | backlit LCD (on keypress) |
Interfaces | Infrared |
Operation | Foil keypad |
Auto – OFF | Yes |
Calibration | Factory calibration and user calibration. Reset to factory calibration possible. |
Internal Storage | internal ring memory for 16 data sets |
Power Supply | 4 batteries (AA) |
Battery Life Time | approx. 53 hours |
Clock | Real Time Clock and Date |
Portability | Portable |
Environmental Conditions | temperature: 5 - 40 °C rel. humidity: 30 - 90 % (non condensing) |
Protection Class | IP 68 |
Compliance | CE |
Dimensions | 110 x 55 x 190 mm |
Weight | 455 g |
Testparameter | Measuring Range | Method No. | Chemical Method |
---|---|---|---|
Ozone T | 0.02 - 2 mg/L O3 | M300 | DPD / Glycine |
Title | Measuring Range | Chemical Method | Packaging Unit | Part Number | Add to quotation cart |
---|---|---|---|---|---|
DPD No.1 | 0.02 - 2 mg/L O3 | DPD / Glycine | Tablet / 100 | 511050BT |
|
DPD No. 1 | 0.02 - 2 mg/L O3 | DPD / Glycine | Tablet / 250 | 511051BT |
|
DPD No. 1 | 0.02 - 2 mg/L O3 | DPD / Glycine | Tablet / 500 | 511052BT |
|
DPD No. 3 | 0.02 - 2 mg/L O3 | DPD / Glycine | Tablet / 100 | 511080BT |
|
DPD No. 3 | 0.02 - 2 mg/L O3 | DPD / Glycine | Tablet / 250 | 511081BT |
|
DPD No. 3 | 0.02 - 2 mg/L O3 | DPD / Glycine | Tablet / 500 | 511082BT |
|
DPD No. 1 High Calcium | 0.02 - 2 mg/L O3 | DPD / Glycine | Tablet / 100 | 515740BT |
|
DPD No. 1 High Calcium | 0.02 - 2 mg/L O3 | DPD / Glycine | Tablet / 250 | 515741BT |
|
DPD No. 1 High Calcium | 0.02 - 2 mg/L O3 | DPD / Glycine | Tablet / 500 | 515742BT |
|
DPD No. 3 High Calcium | 0.02 - 2 mg/L O3 | DPD / Glycine | Tablet / 100 | 515730BT |
|
DPD No. 3 High Calcium | 0.02 - 2 mg/L O3 | DPD / Glycine | Tablet / 250 | 515731BT |
|
DPD No. 3 High Calcium | 0.02 - 2 mg/L O3 | DPD / Glycine | Tablet / 500 | 515732BT |
|
Glycine | 0.02 - 2 mg/L O3 | DPD / Glycine | Tablet / 100 | 512170BT |
|
Glycine | 0.02 - 2 mg/L O3 | DPD / Glycine | Tablet / 250 | 512171BT |
|
Set DPD No. 1/No. 3 100 Pc. | 0.02 - 2 mg/L O3 | DPD / Glycine | 100 each | 517711BT |
|
Set DPD No. 1/No. 3 250 Pc. | 0.02 - 2 mg/L O3 | DPD / Glycine | 250 each | 517712BT |
|
Set DPD No. 1/No. 3 High Calcium 100 Pc. | 0.02 - 2 mg/L O3 | DPD / Glycine | 100 each | 517781BT |
|
Set DPD No. 1/No. 3 High Calcium 250 Pc. | 0.02 - 2 mg/L O3 | DPD / Glycine | 250 each | 517782BT |
|
Set DPD No. 1/Glycine 100 Stck. | 0.02 - 2 mg/L O3 | DPD / Glycine | 100 each | 517731BT |
|
Set DPD No. 1/Glycine 250 Stck. | 0.02 - 2 mg/L O3 | DPD / Glycine | 250 each | 517732BT |
|
- Instrument in plastic case with 4 batteries (AA)
- 3 Round vials with lids
- Sealing rings
- 1 Stirring rod
- 1 Brush
- 1 Syringe (depending on version)
- 100 tablet reagents DPD No. 1
- 100 tablet reagents DPD No. 3 Evo
- 100 tablet reagents Glycine
- Instruction manual
- Manual of Methods
- Certificate (COC)
- Warranty information