Water Treatment Engineers Test Kit (advanced)
Advanced test equipment for water treatment professionals
- All instruments & reagents for daily routine
- Including advanced photometer MD640 for additional parameters
- Early prevention & detection of risks
- Ensure system performance & operating costs
This kit contains pocket meters, checkit comparator, drop tests and MD640 photometer for advanced testing an extended range of control parameters.
Take the complete equipment for direct on-site analysis in practical case in one hand.
Advances analysis of all types of industrial water with visual, electrochemical and photometric methods.
Part Number 56K701500
Aplicaciones
- Agua de caldera
- Agua de refrigeración
- Control de aguas de piscina
- Control de desinfección
- Galvanizado
- Others
- Tratamiento de aguas de aporte
- Tratamiento de aguas potables
- Tratamiento de aguas residuales
Información sobre el producto
Water treatment engineers are engaged daily in the control of water quality in closed circuits, evaporative cooling systems and boiler systems. They need realiable equipment and accurate results to rely on. Both have an important impact on descions on treatment programs and optimal sytem performance
This Advanced Engineers Kit contains all you need to protect the life of the plant and operating costs. It allows early detection of corrosion, scale and biofouling and the investigation of increased biological activity.
Includes the following parameters: Conductivity, pH, glycol, aluminium, bromine, chlorine, copper, iron, molybdate, phosphate and alkalinity (M, P, OH).
Parámetros de prueba | Rango de medición | Número del método | Método químico |
---|---|---|---|
Alcalinidad (P, M, OH) | 50 - 2400 mg/L CaCO3 | 56I700130 | |
Aluminio T | 0.01 - 0.3 mg/L Al | M40 | Eriocromcianina R |
Bromo T | 0.05 - 13 mg/L Br2 | M80 | DPD |
Chloride | 20 - 12000 mg/L Cl- | 56I700190 | |
Cloro T | 0.01 - 6.0 mg/L Cl2 | M100 | DPD |
Cobre T | 0.05 - 5 mg/L Cu | M150 | Biquinolina |
Conductivity | 0 - 200 mS/cm | SD 335 | |
Dureza, total | 5 - 600 mg/L CaCO3 | 56I700280 | |
Dureza (Sí/No) |
8 - 20 mg/L CaCO3 | Y/N | |
Fosfato HR T | 0.33 - 26 mg/L P | M321 | Vanadomolibdato |
Fosfonato | 0 - 20 mg/L HEDP | 56I700320 | |
Glicol | % PEG/MEG | Glycol/Refractometer | |
Hardness Calcium | 5 - 600 mg/L CaCO3 | 56I700270 | |
Hierro HR L | 0.1 - 10 mg/L Fe | M227 | Tioglicolato |
Hierro LR L (A) | 0.03 - 2 mg/L Fe | M225 | Ferrocina / Tioglicolato |
Hydrogen Peroxide | 15 - 500 mg/L H2O2 | 56I700290 | |
Molibdato T | 1 - 50 mg/L MoO4 | M250 | Tioglicolato |
Nitrito |
10 - 2000 mg/L NaNO2 | 56I700300 | |
pH | -2 - 16 | ||
PTSA | 10 - 400 ppb | M501 | Fluorescencia |
Sulfito | 25 - 150 mg/L Na2SO3 | 56I700360 | |
Tanino | 50 - 300 mg/L Tannin | 56I700370 |
Título | Rango de medición | Método químico | Unidad de embalaje | Referencia No | Agregar al carrito de cotizaciones |
---|---|---|---|---|---|
KS139-TA3 Titulante para alcalinidad LR | 50 - 2400 mg/L CaCO3 | 65 mL | 56L013965 |
|
|
KS136-Titulante para alcalinidad HR | 50 - 2400 mg/L CaCO3 | 65 mL | 56L013665 |
|
|
Acidez / Alcalinidad P Indicador PA1 | 50 - 2400 mg/L CaCO3 | 65 mL | 56L013565 |
|
|
KS137-Solución de cloruro de bario | 50 - 2400 mg/L CaCO3 | 65 mL | 56L013765 |
|
|
KS142-CC2-Titulante para cloruro LR | 20 - 12000 mg/L Cl- | 65 mL | 56L014265 |
|
|
KS141-BC2-Titulante para cloruro HR | 20 - 12000 mg/L Cl- | 65 mL | 56L014165 |
|
|
Indicador de cloruro BC1/CC1, 65 mL | 20 - 12000 mg/L Cl- | 65 mL | 56L714065 |
|
|
Tampón de dureza cálcica CH2 | 5 - 600 mg/L CaCO3 | 65 mL | 56L014465 |
|
|
KP216-CH1P-Indicador dureza cálcica | 5 - 600 mg/L CaCO3 | Polvos / 20 g | 56P021620 |
|
|
KS162-TH3-Titulante para dureza LR 65 ml | 5 - 600 mg/L CaCO3 | 65 mL | 56L016265 |
|
|
KS145-H-TH3-CH3-Titulante para dureza HR 65 ml | 5 - 600 mg/L CaCO3 | 65 mL | 56L014565 |
|
|
Hardness Total Indicator TH1P | 5 - 600 mg/L CaCO3 | Polvos / 40 g | 56P028340 |
|
|
Tampón dureza total TH2 | 5 - 600 mg/L CaCO3 | 65 mL | 56L016065 |
|
|
Dureza Sí/No | 8 - 20 mg/L CaCO3 | Tabletas / 100 | 515360BT |
|
|
Indicador de ferroína N1 | 10 - 2000 mg/L NaNO2 | 65 mL | 56L017165 |
|
|
Titulante para nitrito N2 | 10 - 2000 mg/L NaNO2 | 65 mL | 56L017265 |
|
|
Phosphonate Neutraliser P1/2 | 0 - 20 mg/L HEDP | 65 mL | 56L070465 |
|
|
Phosphonate Indicator P4L | 0 - 20 mg/L HEDP | 65 mL | 56L017565 |
|
|
Phosphonate pH Adjuster P3 | 0 - 20 mg/L HEDP | 65 mL | 56L718365 |
|
|
KS176-P5-Titulante para fosfonato | 0 - 20 mg/L HEDP | 65 mL | 56L017665 |
|
|
KP186-S1-Indicador almidón ácido | 25 - 150 mg/L Na2SO3 | Polvos / 40 g | 56P018640 |
|
|
KS187-S2-Titulante para sulfito | 25 - 150 mg/L Na2SO3 | 65 mL | 56L018765 |
|
|
KP146-TN1-CL1P-TO3-CD4-Ácido sulfámico | 50 - 300 mg/L Tannin | Polvos / 50 g | 56P014650 |
|
|
Titrante de tanino TN2 | 50 - 300 mg/L Tannin | 65 mL | 56L019965 |
|
|
Tampón peróxido de hidrógeno HP1 | 15 - 500 mg/L H2O2 | 65 mL | 56L041565 |
|
|
Peróxido de hidrógeno HR Titrant HP2 | 15 - 500 mg/L H2O2 | 65 mL | 56L719965 |
|
|
Peróxido de hidrógeno LR Titrant HP3 | 15 - 500 mg/L H2O2 | 65 mL | 56L649665 |
|
|
Aluminio nº 1 | 0.01 - 0.3 mg/L Al | Eriocromcianina R | Tabletas / 100 | 515460BT |
|
Aluminio nº 1 | 0.01 - 0.3 mg/L Al | Eriocromcianina R | Tabletas / 250 | 515461BT |
|
Aluminio nº 2 | 0.01 - 0.3 mg/L Al | Eriocromcianina R | Tabletas / 100 | 515470BT |
|
Aluminio nº 2 | 0.01 - 0.3 mg/L Al | Eriocromcianina R | Tabletas / 250 | 515471BT |
|
Juego aluminio nº 1/nº 2 | 0.01 - 0.3 mg/L Al | Eriocromcianina R | 100 cada | 517601BT |
|
Juego aluminio nº 1/nº 2 | 0.01 - 0.3 mg/L Al | Eriocromcianina R | 250 cada | 517602BT |
|
DPD nº1 | 0.05 - 13 mg/L Br2 | DPD | Tabletas / 100 | 511050BT |
|
DPD nº 1 | 0.05 - 13 mg/L Br2 | DPD | Tabletas / 250 | 511051BT |
|
DPD nº 1 | 0.05 - 13 mg/L Br2 | DPD | Tabletas / 500 | 511052BT |
|
DPD nº 1 High Calcium | 0.05 - 13 mg/L Br2 | DPD | Tabletas / 100 | 515740BT |
|
DPD nº 1 High Calcium | 0.05 - 13 mg/L Br2 | DPD | Tabletas / 250 | 515741BT |
|
DPD nº 1 High Calcium | 0.05 - 13 mg/L Br2 | DPD | Tabletas / 500 | 515742BT |
|
DPD nº 3 | 0.01 - 6.0 mg/L Cl2 a) | DPD | Tabletas / 100 | 511080BT |
|
DPD nº 3 | 0.01 - 6.0 mg/L Cl2 a) | DPD | Tabletas / 250 | 511081BT |
|
DPD nº 3 | 0.01 - 6.0 mg/L Cl2 a) | DPD | Tabletas / 500 | 511082BT |
|
DPD nº 3 High Calcium | 0.01 - 6.0 mg/L Cl2 a) | DPD | Tabletas / 100 | 515730BT |
|
DPD nº 3 High Calcium | 0.01 - 6.0 mg/L Cl2 a) | DPD | Tabletas / 250 | 515731BT |
|
DPD nº 3 High Calcium | 0.01 - 6.0 mg/L Cl2 a) | DPD | Tabletas / 500 | 515732BT |
|
DPD nº 4 | 0.01 - 6.0 mg/L Cl2 a) | DPD | Tabletas / 100 | 511220BT |
|
DPD nº 4 | 0.01 - 6.0 mg/L Cl2 a) | DPD | Tabletas / 250 | 511221BT |
|
DPD nº 4 | 0.01 - 6.0 mg/L Cl2 a) | DPD | Tabletas / 500 | 511222BT |
|
DPD nº 3 Evo | 0.01 - 6.0 mg/L Cl2 a) | DPD | Tabletas / 100 | 511420BT |
|
DPD nº 3 Evo | 0.01 - 6.0 mg/L Cl2 a) | DPD | Tabletas / 250 | 511421BT |
|
DPD nº 3 Evo | 0.01 - 6.0 mg/L Cl2 a) | DPD | Tabletas / 500 | 511422BT |
|
DPD nº4 Evo | 0.01 - 6.0 mg/L Cl2 a) | DPD | Tabletas / 100 | 511970BT |
|
DPD nº 4 Evo | 0.01 - 6.0 mg/L Cl2 a) | DPD | Tabletas / 250 | 511971BT |
|
DPD nº 4 Evo | 0.01 - 6.0 mg/L Cl2 a) | DPD | Tabletas / 500 | 511972BT |
|
Cobre nº 1 | 0.05 - 5 mg/L Cua) | Biquinolina | Tabletas / 100 | 513550BT |
|
Cobre nº 1 | 0.05 - 5 mg/L Cua) | Biquinolina | Tabletas / 250 | 513551BT |
|
Cobre nº 2 | 0.05 - 5 mg/L Cua) | Biquinolina | Tabletas / 100 | 513560BT |
|
Cobre nº 2 | 0.05 - 5 mg/L Cua) | Biquinolina | Tabletas / 250 | 513561BT |
|
Juego cobre nº 1/nº 2 | 0.05 - 5 mg/L Cua) | Biquinolina | 100 cada | 517691BT |
|
Juego cobre nº 1/nº 2 | 0.05 - 5 mg/L Cua) | Biquinolina | 250 cada | 517692BT |
|
ValidCheck cobre 2 mg/l | 0.05 - 5 mg/L Cua) | Biquinolina | 1 Cantidad | 48141525 |
|
KP962-Polvo de persulfato amónico | 0.03 - 2 mg/L Fe | Ferrocina / Tioglicolato | Polvos / 40 g | 56P096240 |
|
KS63-FE6-Tioglicolato/molibdato HR RGT | 0.03 - 2 mg/L Fe | Ferrocina / Tioglicolato | 30 mL | 56L006330 |
|
KS63-FE6-Tioglicolato/molibdato HR RGT | 0.03 - 2 mg/L Fe | Ferrocina / Tioglicolato | 65 mL | 56L006365 |
|
KS61-FE5-Ferrocina/tioglicolato | 0.03 - 2 mg/L Fe | Ferrocina / Tioglicolato | 65 mL | 56L006165 |
|
Acidez / Alcalinidad P Indicador PA1 | 0.1 - 10 mg/L Fe | Tioglicolato | 30 mL | 56L013530 |
|
Tampón de dureza cálcica CH2 | 0.1 - 10 mg/L Fe | Tioglicolato | 5 x 65 mL mL | 56L014472 |
|
Iron HR Reagent Set | 0.1 - 10 mg/L Fe | Tioglicolato | 1 Cantidad | 56R023590 |
|
Molibdato HR nº 1 | 1 - 50 mg/L MoO4 | Tioglicolato | Tabletas / 100 | 513060BT |
|
Molibdato HR nº 1 | 1 - 50 mg/L MoO4 | Tioglicolato | Tabletas / 250 | 513061BT |
|
Molibdato HR nº 2 | 1 - 50 mg/L MoO4 | Tioglicolato | Tabletas / 100 | 513070BT |
|
Molibdato HR nº 2 | 1 - 50 mg/L MoO4 | Tioglicolato | Tabletas / 250 | 513071BT |
|
Juego molibdato nº 1/nº 2 | 1 - 50 mg/L MoO4 | Tioglicolato | 100 cada | 517631BT |
|
Juego molibdato nº 1/nº 2 | 1 - 50 mg/L MoO4 | Tioglicolato | 250 cada | 517632BT |
|
Juego fosfato nº 1 HR/nº 2 HR | 0.33 - 26 mg/L P | Vanadomolibdato | 100 cada | 517661BT |
|
Fosfato HR P1 | 0.33 - 26 mg/L P | Vanadomolibdato | Tabletas / 100 | 515810BT |
|
Fosfato HR P2 | 0.33 - 26 mg/L P | Vanadomolibdato | Tabletas / 100 | 515820BT |
|
Solución estándar PTSA, 1.000 ppb | 10 - 400 ppb | Fluorescencia | 1 Cantidad | 461210 |
|
Título | Referencia No | Agregar al carrito de cotizaciones |
---|---|---|
Jeringuilla, plástico, 20 mL | 56A006501 |
|
Recipiente de valoración con tapa, plástico, 60 mL | 56A006701 |
|
Jeringuilla de plástico, 5 mL | 56A008501 |
|
Tubo de ensayo 5/10 mL + tapa | 56A600401 |
|
Jeringuilla de plástico 1 ml | 56A013501 |
|
LC 12 para SD 320 / SD 325 Con, hasta 200 mS/cm | 19805040 |
|
ValidCheck cloro 1,5 mg/l | 48105510 |
|
SD 335 Multi (instrumento básico) | 724830 |
|
Refractómetro glicol | 56M000401 |
|
- Plastic case
- 6 Cuvettes 24 mm round with lids & sealing rings
- SD 335 Multi
- MD640 Photometer
- Brush, 11 cm length
- DPD No.1 tablets BT
- DPD No.3 tablets
- Glycine tablets
- DPD Nitrite tablets bottle
- Aluminium No.1 tablets
- Aluminium No.2 tablets
- Copper No.1 Test tablets
- Copper No.2 Test tablets
- Molybdate No.1 tablets
- Molybdate No.2 tablets
- Phosphate H.R.P1 tablets
- Phosphate H.R.P2 tablets
- Copper/Zinc L.R.Test Tablets
- Hardness Yes/No tablets
- pH Buffer 4 solution
- pH Buffer 7 solution
- pH Buffer 10 solution
- 1413uS Standard Conductivity Solution
- Iron Reagent FE6
- Iron Reagent FE5
- Alkalinity 4.5 Indicator TA4
- Alkalinity LR Titrant TA3
- Alkalinity HR Titrant PA2/TA2
- Alkalinity OH Reagent
- Hardness Total Buffer TH2
- Hardness Total Indicator TH1P
- Hardness LR Titrant TH3
- Hardness HR Titrant TH4
- Chloride LR Titrant CC2
- Chloride HR Titrant BC2
- Tannin Indicator TN1
- Tannin Titrant TN2
- Acetic acid 20%
- Nitrite Titrant N2
- Phosphonate Titrant P5
- Hydrogen Peroxide Buffer HP1
- Phosphonate Indicator P4L
- Nitrite Indicator N1
- Hydrogen Peroxide HR Titrant HP2
- Iron Reagent FE8
- Phosphonate pH Adjuster P3
- Chloride Indicator CC1
- Calcium Hardness Indicator CH1P
- Calcium Hardness Buffer CH2
- Phosphonate Neutraliser P1/2
- Sulphite Indicator S1
- Sulphite Indicator S2
- Syringe plastic, 20 mL
- 2 Titration jars with cap, plastic, 60 mL
- Titration jar with cap, plastic, 250 mL
- Wash Bottle 250 mL
- Syringe Filter Holder 25 mm
- Filter Circles GF/C, 25 mm
- Filter Circle 0.45 μm, 25 mm
- Syringe, plastic, 1 mL
- Stirring rod and powder spoon
- Wide neck bottle with lid, 250 mL
- Glycol Refractometer, RHA-218ATC
- Instruction manual