PFXi-195/5
Colour Measurement for Pharmaceutical Solutions
- Integrated RCMSi Technology for Remote Calibration*
- Automatic and Non-subjective Colour Measurement
- Consistent Data Compliant with International Standards
- Very Rugged, Chemically Resistant, Steel Construction
The PFXi series of spectrophotometric colorimeters introduces a unique concept in liquid colour control: RCMSi technology. You can benefit from the capability for remote calibration and servicing via the internet - saving the cost and time associated with servicing and guaranteeing compliance with standards.
The PFXi range is supplied with a full range of colour scales for specific markets including, but not limited to, Petroleum, Edible Oils, Pharmaceuticals, Brewing and Honey. Users can upgrade scales remotely at any time.
Note: When dealing with materials such as fats and waxes whose temperature needs to be maintained at a constant temperature +10°C above the "Cloud Point" of the material, the PFXi-880, -950 & -995 series should be considered. These are available with an additional critical feature, an optional integrated heater unit.
Part Number 1371955
Applications
- Household Products
- Medical and Clinical Products
- Pharmaceuticals and Cosmetics
Product information
-
Integrated RCMSi Technology for Remote Calibration
The PFXi series of spectrophotometric colorimeters introduces a unique concept in liquid colour control: RCMSi technology (Remote Calibration & Maintenance Service via internet). You can now benefit from the capability for remote calibration and servicing via the internet - eliminating any costs and time delays associated with servicing and guaranteeing compliance with standards.
Watch the RCMSi video to see how easy the procedure is. -
Automatic and Non-subjective Colour Measurement
The PFXi range provides absolute results. Automatic instruments communicate in clear terms, accurately and reliably with no opportunity for human error or misjudgement. -
Consistent Data Compliant with International Standards
The PFXi range automatically measures colour and displays results directly, either according to the traditional grading scales that have been wideley adopted as industry standards for colour assessment and control, or in terms of internationally recognised CIE values and spectral data. -
Very Rugged, Chemically Resistant, Steel Construction
The robust steel construction enables you to use the PFXi even in the harshest of environments. -
Easy Maintenance with Removable Sample Chamber
The instruments include a robust steel sample chamber which is easily removed so you can clean it or replace it should spillage occur. -
Extensive and Flexible Choice of Colour Scales
You can choose from a selection of over 20 different, internationally recognised scales in a variety of combinations. -
Remote Upgrade Facility
Uniquely, however, you do not need to make the choice of scales at point of purchase. The PFXi instruments are upgradeable in the field - so you can add a scale at a later date. -
Calculation and Description of "Off-Hue" Status
This is a useful facility that enables you to reveal whether the sample colour is characteristic of the selected scale. Where appropriate, it includes a description of hue difference (eg. redder, greener), relative saturation (stronger or weaker) and an off-hue factor (a relative measure of the distance away in colour space of the sample colour from the "true" colour scale). -
Supplied with Colour Control Software for Data Analysis
The software allows you to generate spectral and CIE diagrams as well as analyse spectral data. It also permits direct control of the instrument from the computer. -
Conformance Standard, Cells and Spare Bulb Included
For regular conformance checking, certified colour reference standards are also available for routine calibration and verification of test data. Conformance filters are supplied with a Certificate of Conformity - giving you the assurance of their colour values and confirmation that they were manufactured under the control of The Tintometer Ltd's ISO 9001 quality system. -
Output Conforming to GLP Including Date, Time, Sample & User ID
The adaptable software and design allow you to configure the PFXi-195 to your requirements. You can set the display language, program the instrument to only display the scales of interest and restrict access to the menu system. -
Accommodates a Wide Range of Sample Cells and Tubes
As well as standard colorimetry cells, the PFXi-195 can be used with a range of tubes and standards, flow-through and disposable spectrophotometer cells. -
Extensive range of accessories
A thermal printer, sample chamber, additional cells, replacement lamps and conformance filters represent some of the additional accessories you can obtain for the PFXi-195.
Note: When dealing with materials such as fats and waxes whose temperature needs to be maintained at a constant temperature +10°C above the "Cloud Point" of the material, the PFXi-880, -950 & -995 series should be considered. These are available with an additional critical feature, an optional integrated heater unit.
Applicable Standard | ASTM D1209 ASTM E308 ISO 6271 Ph.Eur. 2.2.2 USP 631 |
Colour Type | Transparent |
Measuring Principle | 9 interference filters |
Repeatability | ±0.0004 (CIE xy Chromaticity) on measurements of de-ionised water |
Detector | blue enhanced photodiode |
Display | 240 x 128, back-lit graphic display, (white on blue) |
Interfaces | USB RS 232 Ethernet |
Path Length | 0.1 - 50 mm |
Measuring Geometrics | 0° - 180° Transmission |
Internal Storage | 100,000+ Messungen |
Measurement Time | less than 30 seconds |
Sample Chamber | max 50mm cells |
Keypad | 23 key tactile membrane keypad; washable polyester with audible feedback |
Instrument Housing | Fabricated steel with tough, textured paint finish |
Spectral Range | 420 - 710 nm |
Bandwidth | 10 nm |
Baseline Calibration | Single key press; fully automated |
Illuminants | CIE Illuminant A CIE Illuminant B CIE Illuminant C CIE Illuminant D65 |
Portability | Benchtop |
Observer | 2°, 10° |
Compliance | CE RoHS WEEE |
Languages User Interface | English, German, French, Italian, Portuguese, Spanish, Russian, Chinese, Japanese |
Dimensions | 435 x 170 x 195 mm |
Title | Scale Path Length | Scale Range | Scale Resolution | Applicable Standard | Add to quotation cart |
---|---|---|---|---|---|
Pt-Co | 50 mm | 0 - 500 mg Pt/l | 0.1 mg Pt/l | ISO 6271 |
|
European Pharmacopoeia (EP) (Ph.Eur. 2.2.2, Japanese Pharmacopoeia 17, method 2.65) | 40 mm | 1 - 7 (R, Y, BY, GY), 1 - 9 B | 0.1 units | Ph.Eur. 2.2.2 |
|
US Pharmacopoeia | 40 mm | A - T | 1 unit | USP 631 |
|
CIE L* a* b | 1 mm - 50 mm | dependant on spectral locus | 0.01 | ASTM E308 |
|
Transmission % | 1 mm - 50 mm | 0 % - 100 % | 0.01 % |
|
|
Optical Density | 1 mm - 50 mm | 0 - 2.5 | 0.0001 |
|
|
Absorbance | 1 mm - 50 mm | 0 - 1 | 0.0001 |
|
|
Delta E* colour difference | 1 mm - 50 mm | dependant on spectral locus | 0.01 |
|
|
xyY chromaticity co-ordinates | 1 mm - 50 mm | 0 - 1 (x,y), 0 - 100 (Y) | 0.0001 (x,y), 0.01 (Y) | ASTM E308 |
|
XYZ Tristimulus | 1 mm - 50 mm | 0 - 100 | 0.01 | ASTM E308 |
|
Title | Part Number | Add to quotation cart |
---|---|---|
PFXi Lamp 5V | 138180 |
|
Replacement Sample Chamber for PFXi 195 | 133830 |
|
Holder for standard spectrophotometer cells (12.5 mm width) | 131907 |
|
Adapter for 10.65 mm tubes | 132800 |
|
Adapter for 33 mm tubes | 132810 |
|
Tube, 10.65 mm diameter | 352290 |
|
Tube, 33 mm diameter for ASTM Color | 352300 |
|
Dark sample cell for CIE values, 1 mm path length | 132820 |
|
Flow through control software | 137690 |
|
Flow through cell, 10 mm path length | 658020 |
|
PFXi IQ/OQ Documentation | 137680 |
|
PFXi Thermal Printer | 137891 |
|
RCMSi Certified Calibration Pack - Full | 134410 |
|
RCMSi Certified Calibration Pack - Conformance | 134420 |
|
RCMSi Certified Calibration Pack - Starter | 134430 |
|
- PFXi Series Instrument
- External Power Supply
- Set of 3 Power Leads (UK, European and United States)
- USB and LAN Cable
- Quick Start Guide
- USB Memory Stick (Containing Manuals)
- RCMSi Starter Pack
- Certificate of Conformity
- Accessory Box with 5 Volt Halogen Lamp, Conformance Filter, 1 x W600/OG/40 Cell, 1 x W600/OG/50 Cell
Title | Glass Standard Values | Filters | Part Number | Add to quotation cart |
---|---|---|---|---|
EP Y |
Approximate Value
|
1 | 131045 |
|
EP Brown Filter Set |
|
2 | 139430 |
|
EP Brown/Yellow Filter Set |
|
2 | 139440 |
|
EP Green/Yellow Filter Set |
|
2 | 139450 |
|
EP Red Filter Set |
|
2 | 139410 |
|
EP Yellow Filter Set |
|
2 | 139420 |
|
Hazen Colour Filter Set |
Approximate values
|
5 | 139570 |
|
US Pharmacopoeia Filter Set |
G, H, P |
3 | 139460 |
|
CIE L*a*b* |
Approximate values
|
1 | 130501 |
|
CIE L*a*b* (with non RCMSi PFXi195) |
Approximate values
|
1 | 130530 |
|