TR 515 Spectrophotometer

  • Identify colour variations, enabling corrective measures to be taken and ensure products meet required standards
  • Reduce waste, rework, and the need for multiple iterations, leading to cost savings
  • Ensure the colour of your product is consistent to meet high customer expectations
  • Perfect for a variety of different industries including paints, coatings, plastics, textiles, printing, food, cosmetics, and creams
The TR 515 offers accurate and reliable colour management that fits in the palm of your hand. The 45°/0° geometry and ergonomic design makes the unit perfect for the whole manufacturing process from use on the plant floor, production line, warehouse, or laboratory.

 

Part Number 403032

1 pc.

Add to quotation cart

Applications

  • Coatings
  • Household Products
  • Plastics
  • Textiles

Product information

How can the TR 515 help you?

  • Consistency
    Colour is often a critical factor in determining the quality of a product. Manufacturers need to ensure that the colours of their products are consistent to meet customers’ expectations. By using the TR 515, you can ensure your products meet these standards.
  • Accuracy
    The TR 515 can identify any variations in colour, enabling manufacturers to take corrective measures and ensure that the products meet the required standards.
  • Efficiency
    Manufacturing processes often involve the use of colourants or dyes. By measuring the colour of these materials, manufacturers can ensure that they are using the correct amount of colourant and avoid waste. The TR 515 can help reduce costs and improve efficiency in the manufacturing process.
  • Cost-effectiveness
    Accurate colour measurement helps in reducing waste, rework, and the need for multiple iterations, leading to cost savings for the manufacturers.
  • Branding
    A product’s colour is often a key part of its branding and marketing. Customers may associate a particular colour with a brand, and manufacturers need to ensure that their products are consistent. By using the TR 515, you can ensure products match the desired brand colour and help maintain a strong brand image.
  • Compliance
    Some industries, such as food and pharmaceuticals, have strict regulations regarding the colour of their products. By using the TR 515, you can ensure that products comply with these regulations and avoid potential legal issues.
Applicable Standard ASTM 313
ASTM D1925
ASTM D7843
ASTM E308
Colour Type Opaque
Optical Geometry 45°/0° (45° ring-shaped illumination, vertical viewing)
Integrating Sphere Size 48 mm
Spectrophotometric Mode Concave Grating
Sensor 256 image Element Double Array CMOS Image Sensor
Repeatability MAV/SCI: ΔE* ≤0.03
Display 3.5 inch TFT colour LCD, Capacitive Touch Screen
Interfaces USB
Bluetooth 4.0
Spectral Interval 10 nm
Measurement Mode Single Measurement, Average Measurement
External Storage 1000 Standards : 30000 Samples
Location Method Camera View Finder Locating
Measured Reflectance Range 0 - 200 %
Measurement Time 1.5 s
Measuring Aperture MAV: ø 8mm / ø 10 mm ; SAV: ø 4 mm / ø 5 mm
Colour Difference Formular ΔE*ab, ΔE*uv, ΔE*94, ΔE*cmc (2:1), ΔE*cmc (1:1), ΔE*00v, ΔE (Hunter)
Battery Life Time 5000 measurements with 8 hours
Other Colorimetric Index WI (ASTM E313, CIE/ISO, AATCC, Hunter)
YI (ASTM D1925, ASTM 313)
MI (Metamerism Index)
Staining Fastness, Colour Fastness, Colour Strength, Opacity
Displayed Data Spectrogram/Values, Samples Chromaticity Values,
Colour Difference Values/Graph, PASS/FAIL Result, Colour Offset
Inter Instrument Agreement Within ΔE*ab 0.15 (Average for 12 BCRA Series II colour tiles)
Spectral Range 400 - 700 nm
Bandwidth 10 nm
Illuminants CIE Illuminant D65
CIE Illuminant A
CIE Illuminant C
CIE Illuminant D50
CIE Illuminant D55
CIE Illuminant D75
CIE Illuminant F1
CIE Illuminant F2
CIE Illuminant F3
CIE Illuminant F4
CIE Illuminant F5
CIE Illuminant F6
CIE Illuminant F7
CIE Illuminant F8
CIE Illuminant F9
CIE Illuminant F10
CIE Illuminant F11
CIE Illuminant F12
Portability Portable
Illuminant Life Span 5 years, more than 3 million measurements
Observer 2° / 10°
Environmental Conditions 0 - 40 °C, 0 - 85 % Relative Humidity (non condensing), Altitude < 2000 m
Stock Conditions -20 - 50 °C, 0 - 85 % Relative Humidity (non condensing)
Languages User Interface English, Chinese
Dimensions 184 x 105 x 77 mm
Title Scale Path Length Scale Range Scale Resolution Applicable Standard Add to quotation cart
ASTM E 313
ASTM D7843 ASTM D7843
CIE 94
CIE L* a* b n/a dependant on spectral locus 0.01 ASTM E308
CIE L* u* v* Colour Space
CIELAB (L*C*h) n/a L*, C*, dependant on spectral locus, 0 - 360° 0.01 ASTM E308
CMC Tolerancing n/a dependant on spectral locus 0.01
Delta E* colour difference n/a dependant on spectral locus 0.01
Delta L*u*v* colour difference dependant on spectral locus
Hunter Lab dependant on spectral locus 0.01
Metamerism Index n/a > 0
Spectral data
Whiteness Index n/a 0 - 100 ASTM 313
xyY chromaticity co-ordinates 0 - 1 (x,y), 0 - 100 (Y) 0.0001 (x,y), 0.01 (Y) ASTM E308
XYZ Tristimulus 0 - 100 0.01 ASTM E308
Yellowness Index n/a dependant on spectral locus 0.1 ASTM 313, ASTM D1925
Title Online Download Type Format Language Direct Download
Datasheet 403032 - TR 515 Spectrophotometer Datasheet PDF (0.20 MB)
Instruction Manual TR 515 Instruction Manual PDF (1.83 MB)
  • TR 515, 45°/0°, Spectrophotometer
  • OnShade PC Software
  • White and Black Calibration Board
  • Dust Cover
  • USB Cable
  • External DC Power Supply
  • USB Stick with User Manuals in English and Chinese
  • Sturdy Carrying Case
Title Glass Standard Values Filters Part Number Add to quotation cart
CIE L*a*b*

Approximate values

  • L* 92a - 3.4 b*26
1 130501