PFXi-950

Colour Measurement for Chemicals, Oils & Fats

  • Integrated RCMSi Technology for Remote Calibration*
  • Optional Heater Keeps Samples Above The "Cloud Point"
  • Automatic and Non-subjective Colour Measurement
  • Unique Long Path Length Chamber - Accommodates up to 6"/153mm Cells

The PFXi series of spectrophotometric colorimeters introduces a unique concept in liquid colour control: RCMSi technology. You can benefit from the capability for remote calibration and servicing via the internet - saving the cost and time associated with servicing and guaranteeing compliance with standards.

The PFXi-880/950/995 series ensure high precision results from the 16 filter wavelength technology. With an extended path length capacity of up to 6" (153 mm) and an optional heater to sustain the temperature of the sample to +10°C above its "cloud point", they meet the demand for consistent and reliable colour data for a wide range of samples.

 

Part Number 1379501

1 pc.

Add to quotation cart

Applications

  • Chemicals
  • Edible Oils and Fats

Product information

  • Integrated RCMSi Technology for Remote Calibration
    The PFXi series of spectrophotometric colorimeters introduces a unique concept in liquid colour control: RCMSi technology (Remote Calibration & Maintenance Service via internet). You can now benefit from the capability for remote calibration and servicing via the internet - eliminating any costs and time delays associated with servicing and guaranteeing compliance with standards.

    Watch the RCMSi video to see how easy the procedure is.
  • 153mm (6") Sample Chamber
    The long path length cell chamber enables you to measure extremely unsaturated, light samples and colour scales which are defined with long path lengths including the Lovibond® RYBN and AOCS Tintometer® colour, guaranteeing compliance with AOCS, ISO and ASTM standards.
  • Optional Integrated Heater Unit
    The PFXi-880, -950 & -995 series are available with an optional integrated heater unit. This is a critical feature when dealing with materials such as fats and waxes whose temperature needs to be maintained at a constant temperature +10°C above the "Cloud Point" of the material.
  • 16 Wavelength Filters
    Ensure high precision, accurate spectral data.
  • Automatic and Non-subjective Colour Measurement
    The PFXi range provides absolute results. Automatic instruments communicate in clear terms, accurately and reliably with no opportunity for human error or misjudgement.
  • Consistent Data Compliant with International Standards
    The PFXi range automatically measures colour and displays results directly, either according to the traditional grading scales that have been wideley adopted as industry standards for colour assessment and control, or in terms of internationally recognised CIE values and spectral data.
  • Very Rugged, Chemically Resistant, Steel Construction
    The robust steel construction enables you to use the PFXi even in the harshest of environments.
  • Easy Maintenance with Removable Sample Chamber
    The instruments include a robust steel sample chamber which is easily removed so you can clean it or replace it should spillage occur.
  • Extensive and Flexible Choice of Colour Scales
    You can choose from a selection of over 20 different, internationally recognised scales in a variety of combinations.
  • Remote Upgrade Facility
    Uniquely, however, you do not need to make the choice of scales at point of purchase. The PFXi instruments are upgradeable in the field - so you can add a scale at a later date.
  • Calculation and Description of "Off-Hue" Status
    This is a useful facility that enables you to reveal whether the sample colour is characteristic of the selected scale. Where appropriate, it includes a description of hue difference (eg. redder, greener), relative saturation (stronger or weaker) and an off-hue factor (a relative measure of the distance away in colour space of the sample colour from the "true" colour scale).
  • Supplied with Colour Control Software for Data Analysis
    The software allows you to generate spectral and CIE diagrams as well as analyse spectral data. It also permits direct control of the instrument from the computer.
  • Conformance Standard, Cells and Spare Bulb Included
    For regular conformance checking, certified colour reference standards are also available for routine calibration and verification of test data. Conformance filters are supplied with a Certificate of Conformity - giving you the assurance of their colour values and confirmation that they were manufactured under the control of The Tintometer Ltd's ISO 9001 quality system.  
  • Output Conforming to GLP Including Date, Time, Sample & User ID
    The adaptable software and design allow you to configure the PFXi to your requirements. You can set the display language, program the instrument to only display the scales of interest and restrict access to the menu system.
  • Accommodates a Wide Range of Sample Cells and Tubes
    As well as standard colorimetry cells, the PFXi-880/950/995 series can be used with a range of tubes and standards, flow-through and disposable spectrophotometer cells.
  • Extensive range of accessories
    A thermal printer, sample chamber, additional cells, replacement lamps and conformance filters represent some of the additional accessories you can obtain for the PFXi Series.
Applicable Standard AOCS Cc 8d-55
AOCS Cc 13b-45
AOCS Cc 13e-92
AOCS Cc 13j-97
ASTM D1544
ASTM D6166
ASTM E308
BS684
IS 548 (part 1)-2010
ISO 15305
ISO 27608
MS 252 : Part 16
MS 817 : Part 12
Colour Type Transparent
Measuring Principle 16 interference filters
Repeatability ±0.0002 CIE xy Chromaticity on measurements of deionised water
Detector blue enhanced photodiode
Display 240 x 128, back-lit graphic display, (white on blue)
Interfaces USB
RS 232
Ethernet
Path Length 0.1 - 153 mm (0.004" - 6")
Measuring Geometrics 0° - 180° transmission
Internal Storage 100,000+ Measurement
Measurement Time less than 30 seconds
Sample Chamber max 6" (153mm) cells
Keypad 23 key tactile membrane keypad; washable polyester with audible feedback
Instrument Housing Fabricated steel with tough, textured paint finish
Spectral Range 420 - 710 nm
Bandwidth 10 nm
Baseline Calibration Single key press; fully automated
Illuminants CIE Illuminant A
CIE Illuminant B
CIE Illuminant C
CIE Illuminant D65
Portability Benchtop
Observer 2°, 10°
Compliance CE
RoHS
WEEE
Languages User Interface English, French, German, Italian, Portuguese, Russian, Spanish, Chinese, Japanese
Dimensions 515 x 170 x 196 mm
Title Scale Path Length Scale Range Scale Resolution Applicable Standard Add to quotation cart
Gardner Colour (ASTM D 1544, ASTM D 6166, AOCS Td 1a, MS 817 Part 10, ISO 4630:2015) 10 mm 0 - 18 0.1 units ASTM D6166
Lovibond® RYBN Colour 1/16" - 6" 0 - 70 R, 0 - 70 Y, 0 - 30 B, 0 - 3 N 0.1 units AOCS Cc 13e-92, AOCS Cc 13j-97, BS684, ISO 15305, ISO 27608, MS 252 : Part 16, MS 817 : Part 12
AOCS-Tintometer Colour 1/4", 1", 5 1/4" 0 - 20 R, 0 - 70 R 0.1 unit R, 1 unit Y AOCS Cc 8d-55, AOCS Cc 13b-45, AOCS Cc 13j-97
Red and Yellow Values to Indian Standard: Sesame, Mustard, Mahua Oil 1/4" 0 - 79.9 R, 0 - 79.9 Y, 0 - 49.9 B, 0 - 3.9 N IS 548 (part 1)-2010
CIE L* a* b 1 mm - 6" dependant on spectral locus 0.01 ASTM E308
Transmission % 1 mm - 6" 0 % - 100 % 0.1 %
Optical Density 1 mm - 6" 0 - 2.5 0.0001
Absorbance 1 mm - 6" 0 - 1 0.0001
Delta xyY colour difference 1 mm - 6" dependant on spectral locus 0.01
Delta XYZ colour difference 1 mm - 6" dependant on spectral locus 0.01
Delta E* colour difference 1 mm - 6" dependant on spectral locus 0.01
Title Online Download Type Format Language Direct Download
Datasheet 1379501 - PFXi-950 Datasheet PDF (0.20 MB)
Instruction Manual PFXi Series Instruction Manual PDF (1.23 MB)
  • PFXi Series Instrument
  • External Power Supply
  • Set of 3 Power Leads (UK, European and United States)
  • USB and LAN Cable
  • Quick Start Guide
  • USB Memory Stick (Containing Manuals)
  • RCMSi Starter Pack
  • Certificate of Conformity
  • Accessory Box with 5 Volt Halogen Lamp, Conformance Filter, 1 x W600/OG/10 Cell, 1 x W600/OG/1" Cell, 1 x W600/OG/5¼" Cell
Title Glass Standard Values Filters Part Number Add to quotation cart
AOCS-Tintometer Filter Set (PFXi 995/950/880)

Approximate Values

  • 0.5R 1.0Y,
  • 3.7R 13.0Y,
  • 6.6R 50Y
3 136900
Gardner

Approximate Values

  • 3
  • 17
2 342000
Gardner Colour Filter Set (PFXi995/950/880)

Approximate Values

  • 2
  • 8
  • 12
  • 17
4 139890
Gardner Colour Filter Set (PFXi195)

Approximate Values

  • 2
  • 8
  • 12
  • 17
4 139880
Gardner - EC2000

Approximate values

  • 11.3
1 135139
Lovibond Red, Yellow, Neutral Filter Set (PFXi 995/950/880)

Approximate Values

  • 0.1R 0.5Y 0.0N
  • 0.5R 1.3Y 0.1N
  • 1.0R 2.6Y 0.1N
  • 1.3R 3.3Y 0.5N
  • 2.0R 5.7Y 0.1N
  • 2.5R 8.6Y 0.1N
  • 3.2R 15.0Y 0.1N
  • 4.0R 22.0Y 0.1N
  • 5.0R 34.0Y 0.1N
  • 7.1R 51.0Y 0.5N
10 139590
Lovibond Red, Yellow, Neutral Filter Set (PFXi 995/950/880)

Approximate Values

  • 0.1R 0.5Y 0.0N
  • 1.0R 2.6Y 0.1N
  • 2.0R 5.7Y 0.1N
  • 3.2R 15.0Y 0.1N
  • 5.0R 34.0Y 0.1N
5 139610
Lovibond Red, Yellow, Blue Filter Set (PFXi 995/950/880)

Approximate Values

  • 1.0R 0.5B
  • 1.3R 0.8B
  • 1.2R 4.3Y 1.2B
  • 2.6R 11.5Y 2.1B
  • 3.4R 15.9Y 2.9B
5 139620
Lovibond Red, Yellow, Neutral (PFXi 995/950/880)

Approximate Values

  • 0.5R 1.3Y 0.1N
  • 1.3R 3.3Y 0.5N
  • 2.5R 8.6Y 0.1N
  • 4.0R 22Y 0.1N
  • 7.1R 51Y 0.5N
5 139630
CIE L*a*b*

Approximate values

  • L* 92a - 3.4 b*26
1 130501
CIE L*a*b* (PFXi)

Approximate values

  • L* 94 a* - 2.9 b*16
1 130500
CIE L*a*b* (with non RCMSi PFXi995/950/880)

Approximate values

  • L* 57 a* 24 b*88
1 130520