Boiler Water Test Kit
For daily expert control of water in boiler systems
- For maintaining & management of boiler systems
- Developed specifically for water engineers & treatment professionals
- Includes equipment for testing the key parameters
- Supports you ensuring optimum operating conditions
Re-circulating cooling water requires carefully chosen chemical treatments. This helps to minimise microbiological contamination, scaling of critical parts such as heat exchangers and to prevent corrosion.
To be most effective, treatments must be maintained within specific control parameters, as excess inhibitor can have as detrimental an affect as too little.
Part Number 56K701170
Applications
- Boiler Water
- Cooling Water
- Others
Product information
This Test Kit has been designed to include the key parameters which enable the monitoring of samples in these water systems ensuring optimum operating conditions are maintained.
Provides accuracy and speed, utilising drop test and comparator reagents together with electronic meters for the most efficient monitoring of water samples to ensure correct water conditions.
This involves testing:
- Boiler water
- Raw make up water
- Softened make up water (requires ZERO hardness levels)
- Condensate returns
- Feedwater (combination of above waters in varying quantities)
Any failure to maintain the correct levels and dosing of the chemical treatments can lead to:
- Corrosion of the system (leaks)
- Formation of scale (blocked pipes)
These can lead to unstable water conditions with potential negative consequences to the life of the plant and operating costs.
Testparameter | Measuring Range | Method No. | Chemical Method |
---|---|---|---|
Alkalinity (P, M, OH) | 50 - 2400 mg/L CaCO3 | 56I700130 | |
Chloride | 20 - 12000 mg/L Cl- | 56I700190 | |
Conductivity | 0 - 20 mS/cm | SD / Con | |
Hardness, total | 5 - 600 mg/L CaCO3 | 56I700280 | |
Hardness (Yes/No) |
8 - 20 mg/L CaCO3 | Y/N | |
pH | 0 - 14 | SD / pH | |
Sulphite | 25 - 150 mg/L Na2SO3 | 56I700360 | |
Tannin | 50 - 300 mg/L Tannin | 56I700370 |
Title | Measuring Range | Packaging Unit | Part Number | Add to quotation cart |
---|---|---|---|---|
Alkalinity 4.5 Indicator TA4 | 50 - 2400 mg/L CaCO3 | 65 mL | 56L013865 |
|
Alkalinity LR Titrant TA3 | 50 - 2400 mg/L CaCO3 | 65 mL | 56L013965 |
|
Alkalinity HR Titrant PA2/TA2 | 50 - 2400 mg/L CaCO3 | 65 mL | 56L013665 |
|
Acidity / Alkalinity P Indicator PA1 | 50 - 2400 mg/L CaCO3 | 65 mL | 56L013565 |
|
Alkalinity OH Reagent PA3 | 50 - 2400 mg/L CaCO3 | 65 mL | 56L013765 |
|
Chloride LR Titrant CC2 | 20 - 12000 mg/L Cl- | 65 mL | 56L014265 |
|
Chloride HR Titrant BC2 | 20 - 12000 mg/L Cl- | 65 mL | 56L014165 |
|
Chloride Indicator BC1/CC1 | 20 - 12000 mg/L Cl- | 65 mL | 56L714065 |
|
Hardness Total Buffer TH2 | 5 - 600 mg/L CaCO3 | 65 mL | 56L016065 |
|
Hardness Total Indicator TH1P | 5 - 600 mg/L CaCO3 | Powder / 40 g | 56P028340 |
|
Hardness LR Titrant TH3 | 5 - 600 mg/L CaCO3 | 65 mL | 56L016265 |
|
Hardness HR Titrant TH4 | 5 - 600 mg/L CaCO3 | 65 mL | 56L014565 |
|
Hardness Yes/No | 8 - 20 mg/L CaCO3 | Tablet / 100 | 515360BT |
|
Sulphite Indicator S1 | 25 - 150 mg/L Na2SO3 | Powder / 40 g | 56P018640 |
|
Sulphite Titrant S2 | 25 - 150 mg/L Na2SO3 | 65 mL | 56L018765 |
|
Tannin Indicator TN1 | 50 - 300 mg/L Tannin | Powder / 50 g | 56P014650 |
|
Tannin Titrant TN2 | 50 - 300 mg/L Tannin | 65 mL | 56L019965 |
|
Title | Part Number | Add to quotation cart |
---|---|---|
Syringe, plastic, 20 mL | 56A006501 |
|
Titration jar with cap, plastic, 60 mL | 56A006701 |
|
Syringe, plastic, 5 mL | 56A008501 |
|
CHECKIT® Comparator | 145000 |
|
Filter GF/C, 25 mm | 56A019950 |
|
SD40 Multi | 720040 |
|
- Plastic case
- SD40 Multi Pocket Tester
- Checkit Comparator
- 0 - 80 mg/L Phosphate HR Checkit Disc
- 2 plastic vials 10mL with lid
- Phosphate HR Comp.Tablets
- Hardness Yes/No Tablets
- pH Buffer 4
- pH Buffer 7
- pH Buffer 10
- 1413uS Standard Conductivity Solution
- Alkalinity 4.5 Indicator TA4
- Alkalinity LR Titrant TA3
- Alkalinity HR Titrant PA2/TA2
- Acidity / Alkalinity P Indicator PA1
- Alkalinity OH Reagent
- Hardness Total Buffer TH2
- Hardness LR Titrant TH3
- Hardness HR Titrant TH4
- Chloride Indicator CC1
- Chloride LR Titrant CC2
- Chloride HR Titrant BC2
- Sulphite Indicator S2
- Tannin Indicator TN1
- Tannin Titrant TN2
- Acetic acid 20%
- Hardness Total Indicator TH1P
- Sulphite Indicator S1
- Syringe plastic, 20 mL
- 2 Titration jars with cap, plastic, 60 mL
- Syringe filter holder, 25mm
- Filter circles GF/C, 25mm