Disinfection Chlorine Dioxide Test Kit
Determination of chlorine dioxide for disinfection
- On-site testing before and after disinfection works
- Non DPD method for the determination of chlorine dioxide
- For control in the treatment of microorganisms
- Simple for use by both technical and non-technical operators
For commercial buildings, especially dormant premises, industry organisations recommend in many countries regular maintenance procedures for hot & cold-water services to prevent infection with bacteria, biofilms & material damage through misdosing.
The Lovibond® Disinfection Chlorine Dioxide Test Kit assists you with testing instruments and reagents for monitoring the correct dosing level.
Chlorine dioxide is stronger than chlorine and guarantees to reach outlying corners of branches water systems even for Legionella prevention.
Numéro d'ordre 56K701140
Applications
- Contrôle de la désinfection
- Eau de refroidissement
Informations sur les produits
Chlorine dioxide (ClO2) kills microorganisms in the water and has a stronger disinfection effect against germs, viruses, bacteria, fungi and algae than the most commonly used chlorine. Legionella are also reliably removed.
In addition, there is the gradual degradation effect on the biofilm as a breeding ground for legionella even at low doses.
The disinfection effect of chlorine dioxide is also almost independent of the pH value. It does not form chloramines and is largely odourless and tasteless.
Paramètres de test | Gamme de mesure | N° méthode | Méthode chimique |
---|---|---|---|
Chlorine Dioxide | 0.16 - 600 mg/L ClO2 | 56I700230 | |
pH | 0 - 14 pH | Strips pH 0-14 |
Titre | Gamme de mesure | Pack contenant | Code | Ajouter au panier de citations |
---|---|---|---|---|
Tampon dioxyde de chlore CD01 | 0.16 - 600 mg/L ClO2 | 65 mL | 56L033965 |
|
Chlorine Dioxide Titrant CDO2 | 0.16 - 600 mg/L ClO2 | 65 mL | 56L150265 |
|
Dioxyde de chlore Réactif de titrage CD02A | 0.16 - 600 mg/L ClO2 | 65 mL | 56L150165 |
|
KS1500-CD03-dioxyde de chlore HR 0,42% | 0.16 - 600 mg/L ClO2 | 65 mL | 56L150065 |
|
Bandelettes pH 0-14 plastique | 0 - 14 pH | 1 Pièces | 56S001290 |
|
Titre | Code | Ajouter au panier de citations |
---|---|---|
Seringue, plastique, 20 mL | 56A006501 |
|
Récipient de titrage avec couvercle, plastique, 250 mL | 56A010501 |
|
- Plastic case
- pH Test Strips, pH 7-14, plastic
- Chlorine Dioxide Buffer CDO1
- Chlorine Dioxide Titrant CDO2
- Chlorine Dioxide Titrant CDO3
- Syringe, plastic, 20 mL
- 2 Titration jars with cap, plastic, 60 mL
- Instruction manual