Disinfection Test Kit (combined)
For disinfection control in all applications
- Determination of all common desinfection methods
- Monitoring the correct concentration for your system
- Control high & low disinfection levels
- Complete Kit for economic & fast results
Building owners and management teams as well as water treatment companies have to control several commercial buildings with different water systems in compliance with current regulations. No matter wheter hot or cold-water services have to be monitored: They have the obligations to take care for safe water.
Our Disinfection Test Kits assist to control formation of biofilms, growth of Legionella bacteria or correct strength of disinfectants. Additionally it avoids system blockages or deposit corrosion and material damage.
The Lovibond® Disinfection Combined Test Kit includes all testing instruments and reagents for monitoring different disinfection methods.
N. ordine 56K701160
Applicazioni
- Acqua di raffreddamento
- Controllo disinfettante
Informazioni sul prodotto
The Lovibond® Combined Disinfection Test Kit should be used in all applications where a system water disinfection is being carried out to ensure full compliance with current regulations.
The comprehensive Kit allows the determination of both chlorine (as Cl2), chlorine dioxide (ClO2) and hydrogen peroxide (as H2O2) at both low & high levels which are required during a system disinfection.
High levels of disinfectant need to be monitored during the procedure to ensure that sufficient disinfectant has been achieved at the tank and all subsequent outlet.
Low levels need to be monitored to ensure that (if appropriate) the system has been fully flushed to remove all disinfectants and the system water is back to the same as mains water quality.
The disinfectant levels must be recorded to ensure full compliance with standards.
Parametri di prova | Campo di misura | Numero metodo | Metodo chimico |
---|---|---|---|
Chlorine Dioxide | 0.16 - 600 mg/L ClO2 | 56I700230 | |
Cloro | 10 - 200 mg/L Cl2 | Strips Cl HR 10-200 | |
Cloro (libero) | 1 - 300 mg/L Cl2 | 56I700200 | |
Hydrogen Peroxide | 15 - 500 mg/L H2O2 | 56I700290 | |
Hydrogen Peroxide test strips | 0.5 - 100 mg/L H2O2 | Strips H2O2 0.5-100 | |
pH | 7 - 14 pH | Strips pH 7-14 |
Titolo | Campo di misura | Unità di imballaggio | N. ordine | Aggiungi al carrello |
---|---|---|---|---|
Cloro libero Tampone FCL1 | 1 - 300 mg/L Cl2 | 65 mL | 56L015165 |
|
Cloro libero LR Titolante FCL2 | 1 - 300 mg/L Cl2 | 65 mL | 56L015265 |
|
Cloro libero HR Titolante FCL3 | 1 - 300 mg/L Cl2 | 65 mL | 56L015365 |
|
Tampone di biossido di cloro CD01 | 0.16 - 600 mg/L ClO2 | 65 mL | 56L033965 |
|
Chlorine Dioxide Titrant CDO2 | 0.16 - 600 mg/L ClO2 | 65 mL | 56L150265 |
|
Titolante del biossido di cloro CD02A | 0.16 - 600 mg/L ClO2 | 65 mL | 56L150165 |
|
KS1500-CD03-Biossido di cloro HR 0,42% | 0.16 - 600 mg/L ClO2 | 65 mL | 56L150065 |
|
Strisce per pH 7-14 Plastica | 7 - 14 pH | 1 pz. | 56S001190 |
|
Strisce reattive per perossido di idrogeno | 0.5 - 100 mg/L H2O2 | 1 pz. | 56S000850 |
|
Tampone perossido di idrogeno HP1 | 15 - 500 mg/L H2O2 | 65 mL | 56L041565 |
|
Perossido di idrogeno HR Titrant HP2 | 15 - 500 mg/L H2O2 | 65 mL | 56L719965 |
|
Perossido di idrogeno LR Titrant HP3 | 15 - 500 mg/L H2O2 | 65 mL | 56L649665 |
|
Titolo | N. ordine | Aggiungi al carrello |
---|---|---|
Siringa, plastica, 20 mL | 56A006501 |
|
Vaso di titolazione con coperchio, plastica, 60 mL | 56A006701 |
|
Vaso di titolazione con coperchio, plastica, 250 mL | 56A010501 |
|
- Plastic case
- pH Test Strips, pH 7-14, plastic
- Chlorine HR Test Strips, 10-200 mg/L
- Hydrogen Peroxide Test Strips, 0.5-100 mg/L
- Free Chlorine Buffer FCL1
- Free Chlorine LR Titrant FCL2
- Free Chlorine HR Titrant FCL3
- Chlorine Dioxide Buffer CDO1
- Hydrogen Peroxide Buffer HP1
- Tannin Titrant TN2
- Hydrogen Peroxide HR Titrant HP2
- Chlorine Dioxide Titrant CDO2
- Chlorine Dioxide Titrant CDO3
- Syringe plastic, 20 mL
- Titration jar with cap, plastic, 60 mL
- Instruction manual