Water Treatment Engineers Test Kit (visual)
Monitoring water treatment for professionals with visual methods
- Mobile laboratory for water treatment monitoring
- Works with visual tests & further methods
- Ensure system performance & operating costs
- Most efficient monitoring of industrial water samples
You need safe, fast and reliable test results?
Take everything you need for chemical analysis of industrial water quality in one hand
This comprehensive Test Kit combines everything water professionals need for on-site analysis with visual test methods and more.
N. ordine 56K701300
Applicazioni
- Acqua di caldaia
- Acqua di raffreddamento
- Controllo disinfettante
- Others
- Trattamento acqua di scarico
Informazioni sul prodotto
The Lovibond®Visual Engineers Test Kit is designed for the water treatment professional to be used on all types of industrial water systems such as cooling towers, closed water systems and steam raising boilers.
The Kit uses visual methods on a comparator. It includes drop tests and pocket meters for electrochemistry parameters.
Each test has been chosen specifically for these applications to ensure accurate repeatable results.
Includes the following parameters: Conductivity, pH, glycol, aluminium, bromine, chlorine, copper, iron, molybdate, phosphate.
Parametri di prova | Campo di misura | Numero metodo | Metodo chimico |
---|---|---|---|
Alkalinity (P, M, OH) | 50 - 2400 mg/L CaCO3 | 56I700130 | |
Alluminio T | 0 - 0.3 mg/L Al | M2501 | Eriocromocianina R |
Bromo T | 0 - 5 mg/L Br2 | M2504 | DPD |
Chloride | 20 - 12000 mg/L Cl- | 56I700190 | |
Cloro MR T | 0 - 2 mg/L Cl2 | M2506 | DPD |
Conduttività | 0 - 20 mS/cm | SD / Con | |
Durezza (Sì/No) |
8 - 20 mg/L CaCO3 | Y/N | |
Durezza totale | 5 - 600 mg/L CaCO3 | 56I700280 | |
Ferro LR T | 0.05 - 1 mg/L Fe | M2513 | PPST |
Fosfato HR T | 0 - 80 mg/L PO4 | M2537 | Molibdato di vanadio |
Glicole | % PEG/MEG | Glycol/Refractometer | |
Hardness | 5 - 600 mg/L CaCO3 | 56I700270 | |
Hydrogen Peroxide | 15 - 500 mg/L H2O2 | 56I700290 | |
Molybdato HR T | 50 - 500 mg/L MoO4 | M2525 | Tioglicolato |
Nitrito |
10 - 2000 mg/L NaNO2 | 56I700300 | |
pH | 0 - 14 | SD / pH | |
Phosphonate | 0 - 20 mg/L HEDP | 56I700320 | |
Rame HR T | 0 - 5 mg/L Cu | M2518 | Bichinolina |
Sulphite | 25 - 150 mg/L Na2SO3 | 56I700360 | |
Tannin | 50 - 300 mg/L Tannin | 56I700370 |
Titolo | Parametro e campo | Classificazione disco colorimetrico | N. ordine | Aggiungi al carrello |
---|---|---|---|---|
CHECKIT® Disc Alluminio | Alluminio T 0 - 0.3 mg/L Al | 0 / 0,01 / 0,02 / 0,03 / 0,04 / 0,05 / 0,06 / 0,07 / 0,08 / 0,09 / 0,1 / 0,15 / 0,2 / 0,25 / 0,3 | 146200 | |
CHECKIT® Disc Bromo | Bromo T 0 - 5 mg/L Br2 | 0 / 0,2 / 0,4 / 0,6 / 0,8 / 1,0 / 1,2 / 1,4 / 1,6 / 1,8 / 2 / 2,5 / 3 / 3,5 / 4 / 4,5 / 5 | 146280 | |
CHECKIT® Disc Cloro DPD | Cloro MR T 0 - 2 mg/L Cl2 | 0,1 / 0,2 / 0,3 / 0,4 / 0,5 / 0,6 / 0,7 / 0,8 / 0,9 / 1,0 / 1,1 / 1,2 / 1,3 / 1,4 / 1,6 / 1,8 / 2,0 | 146040 | |
CHECKIT® Disc Rame HR, libero e totale | Rame HR T 0 - 5 mg/L Cu | 0 / 0,5 / 1,0 / 1,5 / 2,0 / 2,5 / 3,0 / 3,5 / 4,0 / 4,5 / 5,0 | 146430 | |
CHECKIT® Disc Ferro LR | Ferro LR T 0.05 - 1 mg/L Fe | 0,05 / 0,1 / 0,15 / 0,2 / 0,25 / 0,3 / 0,35 / 0,4 / 0,45 / 0,5 / 0,55 / 0,6 / 0,65 / 0,7 / 0,75 / 0,8 / 0,9 / 1,0 | 146220 | |
CHECKIT® Disc Molibdato HR | Molybdato HR T 50 - 500 mg/L MoO4 | 50 / 100 / 150 / 200 / 250 / 300 / 500 | 146295 | |
CHECKIT® Disc Fosfato HR | Fosfato HR T 0 - 80 mg/L PO4 | 0 / 5 / 10 / 15 / 20 / 25 / 30 / 35 / 40 / 45 / 50 / 55 / 60 / 65 / 70 / 75 / 80 | 146250 |
Titolo | Campo di misura | Metodo chimico | Unità di imballaggio | N. ordine | Aggiungi al carrello |
---|---|---|---|---|---|
KS138-TA4-4,5 Indicatore | 50 - 2400 mg/L CaCO3 | 65 mL | 56L013865 |
|
|
KS139-TA3 Titolante alcalinità LR | 50 - 2400 mg/L CaCO3 | 65 mL | 56L013965 |
|
|
KS136-Titolante alcalinità HR | 50 - 2400 mg/L CaCO3 | 65 mL | 56L013665 |
|
|
Acidità / Alcalinità P Indicatore PA1 | 50 - 2400 mg/L CaCO3 | 65 mL | 56L013565 |
|
|
KS137-Soluzione di cloruro di bario | 50 - 2400 mg/L CaCO3 | 65 mL | 56L013765 |
|
|
KS142-CC2-Titolante per cloruro LR | 20 - 12000 mg/L Cl- | 65 mL | 56L014265 |
|
|
KS141-BC2- Titolante per cloruro HR | 20 - 12000 mg/L Cl- | 65 mL | 56L014165 |
|
|
Indicatore di cloruro BC1/CC1, 65 mL | 20 - 12000 mg/L Cl- | 65 mL | 56L714065 |
|
|
Tampone di durezza del calcio CH2 | 5 - 600 mg/L CaCO3 | 65 mL | 56L014465 |
|
|
KP216- CH1P Indicatore di durezza calcica | 5 - 600 mg/L CaCO3 | Polvere / 20 g | 56P021620 |
|
|
KS162-TH3-Titolante durezza LR 65 ml | 5 - 600 mg/L CaCO3 | 65 mL | 56L016265 |
|
|
KS145-H-TH3-CH3-Titolante durezza HR 65 ml | 5 - 600 mg/L CaCO3 | 65 mL | 56L014565 |
|
|
Hardness Total Indicator TH1P | 5 - 600 mg/L CaCO3 | Polvere / 40 g | 56P028340 |
|
|
Tampone durezza totale TH2 | 5 - 600 mg/L CaCO3 | 65 mL | 56L016065 |
|
|
Durezza Sì/No | 8 - 20 mg/L CaCO3 | Pastiglia / 100 | 515360BT |
|
|
Indicatore di ferroina N1 | 10 - 2000 mg/L NaNO2 | 65 mL | 56L017165 |
|
|
Titolante nitrito N2 | 10 - 2000 mg/L NaNO2 | 65 mL | 56L017265 |
|
|
Phosphonate Neutraliser P1/2 | 0 - 20 mg/L HEDP | 65 mL | 56L070465 |
|
|
Phosphonate Indicator P4L | 0 - 20 mg/L HEDP | 65 mL | 56L017565 |
|
|
Phosphonate pH Adjuster P3 | 0 - 20 mg/L HEDP | 65 mL | 56L718365 |
|
|
KS176-P5-Titolante per fosfonati | 0 - 20 mg/L HEDP | 65 mL | 56L017665 |
|
|
KP186-S1-Indicatore amido acido | 25 - 150 mg/L Na2SO3 | Polvere / 40 g | 56P018640 |
|
|
KS187-S2-Titolante per solfito | 25 - 150 mg/L Na2SO3 | 65 mL | 56L018765 |
|
|
KP146-TN1-CL1P-TO3-CD4-Acido solfamico | 50 - 300 mg/L Tannin | Polvere / 50 g | 56P014650 |
|
|
Tannino Titrante TN2 | 50 - 300 mg/L Tannin | 65 mL | 56L019965 |
|
|
Tampone perossido di idrogeno HP1 | 15 - 500 mg/L H2O2 | 65 mL | 56L041565 |
|
|
Perossido di idrogeno HR Titrant HP2 | 15 - 500 mg/L H2O2 | 65 mL | 56L719965 |
|
|
Perossido di idrogeno LR Titrant HP3 | 15 - 500 mg/L H2O2 | 65 mL | 56L649665 |
|
|
Alluminio No. 1 | 0 - 0.3 mg/L Al | Eriocromocianina R | Pastiglia / 100 | 515460BT |
|
Alluminio No. 1 | 0 - 0.3 mg/L Al | Eriocromocianina R | Pastiglia / 250 | 515461BT |
|
Alluminio No. 2 | 0 - 0.3 mg/L Al | Eriocromocianina R | Pastiglia / 100 | 515470BT |
|
Alluminio No. 2 | 0 - 0.3 mg/L Al | Eriocromocianina R | Pastiglia / 250 | 515471BT |
|
Set Alluminio No. 1/no. 2 | 0 - 0.3 mg/L Al | Eriocromocianina R | ciascuna 100 | 517601BT |
|
Set Alluminio No. 1/no. 2 | 0 - 0.3 mg/L Al | Eriocromocianina R | ciascuna 250 | 517602BT |
|
DPD No. 1 Rapido | 0 - 5 mg/L Br2 | DPD | Pastiglia / 100 | 511310BT |
|
DPD No. 1 Rapido | 0 - 5 mg/L Br2 | DPD | Pastiglia / 250 | 511311BT |
|
DPD No. 1 Rapido | 0 - 5 mg/L Br2 | DPD | Pastiglia / 500 | 511312BT |
|
DPD No. 3 Rapido | 0 - 2 mg/L Cl2 | DPD | Pastiglia / 100 | 511290BT |
|
DPD No. 3 Rapido | 0 - 2 mg/L Cl2 | DPD | Pastiglia / 250 | 511291BT |
|
DPD No. 3 Rapido | 0 - 2 mg/L Cl2 | DPD | Pastiglia / 500 | 511292BT |
|
DPD No. 4 Rapido | 0 - 2 mg/L Cl2 | DPD | Pastiglia / 100 | 511570BT |
|
DPD No. 4 Rapido | 0 - 2 mg/L Cl2 | DPD | Pastiglia / 250 | 511571BT |
|
DPD No. 4 Rapido | 0 - 2 mg/L Cl2 | DPD | Pastiglia / 500 | 511572BT |
|
Rame No. 1 | 0 - 5 mg/L Cu | Bichinolina | Pastiglia / 100 | 513550BT |
|
Rame No. 1 | 0 - 5 mg/L Cu | Bichinolina | Pastiglia / 250 | 513551BT |
|
Rame No. 2 | 0 - 5 mg/L Cu | Bichinolina | Pastiglia / 100 | 513560BT |
|
Rame No. 2 | 0 - 5 mg/L Cu | Bichinolina | Pastiglia / 250 | 513561BT |
|
Set Rame No. 1/no. 2 | 0 - 5 mg/L Cu | Bichinolina | ciascuna 100 | 517691BT |
|
Set Rame No. 1/no. 2 | 0 - 5 mg/L Cu | Bichinolina | ciascuna 250 | 517692BT |
|
Ferro II LR | 0.05 - 1 mg/L Fe | PPST | Pastiglia / 100 | 515420BT |
|
Ferro II LR | 0.05 - 1 mg/L Fe | PPST | Pastiglia / 250 | 515421BT |
|
Ferro LR | 0.05 - 1 mg/L Fe | PPST | Pastiglia / 100 | 515370BT |
|
Ferro LR | 0.05 - 1 mg/L Fe | PPST | Pastiglia / 250 | 515371BT |
|
Molibdato HR No. 1 | 50 - 500 mg/L MoO4 | Tioglicolato | Pastiglia / 100 | 513060BT |
|
Molibdato HR No. 1 | 50 - 500 mg/L MoO4 | Tioglicolato | Pastiglia / 250 | 513061BT |
|
Molibdato HR No. 2 | 50 - 500 mg/L MoO4 | Tioglicolato | Pastiglia / 100 | 513070BT |
|
Molibdato HR No. 2 | 50 - 500 mg/L MoO4 | Tioglicolato | Pastiglia / 250 | 513071BT |
|
Set Molibdato No. 1/no. 2 | 50 - 500 mg/L MoO4 | Tioglicolato | ciascuna 100 | 517631BT |
|
Set Molibdato No. 1/no. 2 | 50 - 500 mg/L MoO4 | Tioglicolato | ciascuna 250 | 517632BT |
|
Fosfati HR | 0 - 80 mg/L PO4 | Molibdato di vanadio | Pastiglia / 100 | 511980BT |
|
Titolo | N. ordine | Aggiungi al carrello |
---|---|---|
Siringa, plastica, 20 mL | 56A006501 |
|
Vaso di titolazione con coperchio, plastica, 60 mL | 56A006701 |
|
Siringa di plastica, 5 mL | 56A008501 |
|
Provetta 5/10 mL + CAP | 56A600401 |
|
Siringa di plastica 1 ml | 56A013501 |
|
CHECKIT® Comparator | 145000 |
|
Rifrattometro per glicole | 56M000401 |
|
- Plastic case
- SD40 Multi Pocket Tester
- Checkit Comparator
- 0 - 5 mg/L Bromine Checkit® Disc
- 0 - 4 mg/L Chlorine DPD Checkit® Disc
- 0 - 1.0 mg/L Iron LR Checkit® Disc
- 50 - 500 mg/L Molybdate HR Checkit® Disc
- 0 - 0.3 mg/L Aluminium Checkit® Disc
- 0 - 5.0 mg/L Copper HR Free & Total Checkit® Disc
- 0 - 80 mg/L Phosphate HR Checkit® Disc
- 1 - 10 mg/L Iron HR Checkit® Disc
- 2 Plastic vials 10 mL with lid
- DPD No.1 Rapid tablets BT
- DPD No.3 Rapid tablets
- Molybdate No.1 tablets
- Molybdate No.2 tablets
- Aluminium No.1 tablets
- Aluminium No.2 tablets
- Copper No.1 Test tablets
- Copper No.2 Test tablets
- Phosphate HR Comp. tablets
- Hardness Yes/No tablets
- pH Buffer 4 solution
- pH Buffer 7 solution
- pH Buffer 10 solution
- 1413uS Standard Conductivity solution
- Iron Reagent FE5
- Iron Reagent FE6
- Chloride LR Titrant CC2
- Chloride HR Titrant BC2
- Alkalinity 4.5 Indicator TA4
- Alkalinity LR Titrant TA3
- Alkalinity HR Titrant PA2/TA2
- Acidity / Alkalinity P Indicator PA1
- Alkalinity OH Reagent
- Hardness Total Indicator TH1P
- Hardness LR Titrant TH3
- Hardness HR Titrant TH4
- Tannin Indicator TN1
- Hydrogen Peroxide HR Titrant HP2
- Acetic acid 20%
- Nitrite Titrant N2
- QAC Buffer QA2
- Phosphonate Indicator P4L
- Nitrite Indicator N1
- Tannin Titrant TN2
- Iron Reagent FE8
- Phosphonate pH Adjuster P3
- Chloride Indicator CC1
- Calcium Hardness Indicator CH1P
- Calcium Hardness Buffer CH2
- Phosphonate Neutraliser P1/2
- Sulphite Indicator S1
- Sulphite Indicator S2
- Glycol Refractometer, RHA-218ATC
- Syringe plastic, 20 mL
- 2 Titration jars with cap, plastic, 60 mL
- Titration jar with cap, plastic, 250 mL
- Wash Bottle 250 mL
- Syringe Filter Holder 25 mm
- Filter Circles GF/C, 25 mm
- Filter Circle 0.45 μm, 25 mm
- Stirring rod and powder spoon
- Syringe, plastic, 1 mL
- 3 Wide neck bottles with lids, 250 mL
- Instruction manual