MD50 Cloro, reagenti liquidi

Precise water control with proven and compact measuring system

  • High-precision optics to ensure accuracy and reproducibility
  • Wired and wireless data transfer option
  • Multiple single parameter variants for diverse applications
The MD50 series offers a comprehensive range of single parameter photometers that meet the most diverse needs of water treatment. With its language-free user interface based on icons and animations, it offers unparalleled ease of use. The robust design of the MD50 ensures that the instrument can withstand the toughest conditions in the field. 

 

N. ordine 280102

1 pz.

Aggiungi al carrello

Applicazioni

  • Acqua di caldaia
  • Acqua di raffreddamento
  • Controllo acqua in vasca
  • Controllo disinfettante
  • Trattamento acqua di scarico
  • Trattamento acqua non depurata
  • Trattamento acqua potabile

Informazioni sul prodotto

The MD50 has several key features that make it a favorite among users.

Robust Design
The MD50 is built to last. Its rugged industrial design, complete with rubber-protected sides and an IP67 rating, ensures unmatched durability and reliability even in demanding environments.

Accurate, Reproducible Results
The innovative optical system of the MD50 delivers exceptional accuracy and speed, ensuring precise readings in record time.

Factory Programmed Methods
All MD50 instruments come with pre-programmed methods for different types of reagents. Simply select the test you need, prepare your sample, and test! To simplify test selection, you can choose the reagent type from the settings and display only your desired methods in the methods list.

User Calibration and User defined Method
A one-point calibration is possible with the MD50. The instrument automatically saves the calibration protocol in the logs along with the calibration factor. All user-calibrated methods are displayed with a calibration icon on the screen. Can't find the method you need? The MD50 also allows you to program a user-defined method using PC software.

One-Time-Zero Function
Save time by zeroing the instrument once for each sample. When testing a new sample, zero the instrument once and all subsequent tests of that sample do not require re-zeroing. You can also activate or deactivate the OTZ function for all methods in the settings.

Automatic Data Storage
The MD50 automatically stores the last 100 readings and protocols with a time and date stamp. Results remain in storage even during a battery exchange.

Data Transfer
The MD50 offers smooth and effortless data transfer. You can transfer data to the AquaLX® app via NFC or use a USB cable to transfer data to PC software. Data can also be exported in CSV format for programs like Excel.

Ergonomic Design
Whether you're using the MD50 in the field or in the lab, its design makes it easy to handle and view the display. In the field, the compact size and side protections ensure a firm grip during use. In the lab, rubber feet on the bottom of the housing eliminate the need for two-handed operation or chasing your instrument around the workbench.

GLP Compliance
To ensure data quality and integrity, the MD50 creates and saves a protocol for each change made during operation.

2-year Warranty
Ottica LED, sensore spettrometrico, filtro antidisturbo (solo varianti selezionate)
Sorgente luminosa LED
Lunghezza d'onda 530
Campo fotometrico 0 - 3 Abs
Cuvette adeguate Cuvette cilindriche 24 mm
Display LCD retroilluminato
Interfacce USB-C
NFC (Near Field Communication)
Formato di trasferimento dati .csv
Funzionamento Tastiera a membrana
Auto – OFF
Programmabilità Sì, con software per PC
Messa a punto Regolazione di fabbrica e utente - possibilità di ritorno alla regolazione di fabbrica in qualsiasi momento
Aggiornamenti Aggiornamento del firmware e dei metodi
Memoria interna Memoria interna ad anello per 100 record di dati
Durata delle batterie circa 5000 misure (senza retroilluminazione)
Portabilità Portatile
Grado di inquinamento 2
Altitudine massima sul livello del mare 3500 m
Condizioni ambientali 5 - 50 °C con un'umidità relativa del 30 - 95 % (senza condensa)
Classe di protezione IP 67
Conformità CE
Lingue del manuale operativo Tedesco, Inglese, Francese, Spagnolo, Italiano, Portoghese, Cinese, Olandese
Dimensioni 155 x 76 x 45 mm
Parametri di prova Campo di misura Numero metodo Metodo chimico
Cloro HR T 0.1 - 10 mg/L Cl2 M103 DPD
Cloro L 0.02 - 4.0 mg/L Cl2 M101 DPD
Cloro PP 0.02 - 2 mg/L Cl2 M110 DPD
Cloro T 0.01 - 6.0 mg/L Cl2 M100 DPD
Titolo Campo di misura Metodo chimico Unità di imballaggio N. ordine Aggiungi al carrello
DPD No.1 0.01 - 6.0 mg/L Cl2 a) DPD Pastiglia / 100 511050BT
DPD No. 1 0.01 - 6.0 mg/L Cl2 a) DPD Pastiglia / 250 511051BT
DPD No. 1 0.01 - 6.0 mg/L Cl2 a) DPD Pastiglia / 500 511052BT
DPD No. 3 0.01 - 6.0 mg/L Cl2 a) DPD Pastiglia / 100 511080BT
DPD No. 3 0.01 - 6.0 mg/L Cl2 a) DPD Pastiglia / 250 511081BT
DPD No. 3 0.01 - 6.0 mg/L Cl2 a) DPD Pastiglia / 500 511082BT
DPD No. 1 Alto Calcio 0.01 - 6.0 mg/L Cl2 a) DPD Pastiglia / 100 515740BT
DPD No. 1 Alto Calcio 0.01 - 6.0 mg/L Cl2 a) DPD Pastiglia / 250 515741BT
DPD No. 1 Alto Calcio 0.01 - 6.0 mg/L Cl2 a) DPD Pastiglia / 500 515742BT
DPD No. 3 High Calcium 0.01 - 6.0 mg/L Cl2 a) DPD Pastiglia / 100 515730BT
DPD No. 3 High Calcium 0.01 - 6.0 mg/L Cl2 a) DPD Pastiglia / 250 515731BT
DPD No. 3 High Calcium 0.01 - 6.0 mg/L Cl2 a) DPD Pastiglia / 500 515732BT
DPD No. 4 0.01 - 6.0 mg/L Cl2 a) DPD Pastiglia / 100 511220BT
DPD No. 4 0.01 - 6.0 mg/L Cl2 a) DPD Pastiglia / 250 511221BT
DPD No. 4 0.01 - 6.0 mg/L Cl2 a) DPD Pastiglia / 500 511222BT
DPD No. 3 Evo 0.01 - 6.0 mg/L Cl2 a) DPD Pastiglia / 100 511420BT
DPD No. 3 Evo 0.01 - 6.0 mg/L Cl2 a) DPD Pastiglia / 250 511421BT
DPD No. 3 Evo 0.01 - 6.0 mg/L Cl2 a) DPD Pastiglia / 500 511422BT
DPD No.4 Evo 0.01 - 6.0 mg/L Cl2 a) DPD Pastiglia / 100 511970BT
DPD No. 4 Evo 0.01 - 6.0 mg/L Cl2 a) DPD Pastiglia / 250 511971BT
DPD No. 4 Evo 0.01 - 6.0 mg/L Cl2 a) DPD Pastiglia / 500 511972BT
DPD 1 soluzione tampone, bottiglia blu 0.02 - 4.0 mg/L Cl2 a) DPD 15 mL 471010
Soluzione tampone DPD 1 0.02 - 4.0 mg/L Cl2 a) DPD 100 mL 471011
DPD 1 Soluzione tampone in confezione da 6 0.02 - 4.0 mg/L Cl2 a) DPD 1 pz. 471016
DPD 1 soluzione reagente, bottiglia verde 0.02 - 4.0 mg/L Cl2 a) DPD 15 mL 471020
Soluzione reagente DPD 1 0.02 - 4.0 mg/L Cl2 a) DPD 100 mL 471021
DPD 1 Soluzione reagente in confezione da 6 0.02 - 4.0 mg/L Cl2 a) DPD 1 pz. 471026
DPD 3 soluzione, bottiglia rossa 0.02 - 4.0 mg/L Cl2 a) DPD 15 mL 471030
Soluzione DPD 3 0.02 - 4.0 mg/L Cl2 a) DPD 100 mL 471031
DPD 3 Soluzione in confezione da 6 0.02 - 4.0 mg/L Cl2 a) DPD 1 pz. 471036
Set di reagenti DPD 0.02 - 4.0 mg/L Cl2 a) DPD 1 pz. 471056
DPD No. 1 HR 0.1 - 10 mg/L Cl2 a) DPD Pastiglia / 100 511500BT
DPD No. 1 HR 0.1 - 10 mg/L Cl2 a) DPD Pastiglia / 250 511501BT
DPD No. 1 HR 0.1 - 10 mg/L Cl2 a) DPD Pastiglia / 500 511502BT
DPD No. 3 HR 0.1 - 10 mg/L Cl2 a) DPD Pastiglia / 100 511590BT
DPD No. 3 HR 0.1 - 10 mg/L Cl2 a) DPD Pastiglia / 250 511591BT
DPD No. 3 HR 0.1 - 10 mg/L Cl2 a) DPD Pastiglia / 500 511592BT
Set DPD No. 1 HR/No. 3 HR 0.1 - 10 mg/L Cl2 a) DPD ciascuna 100 517791BT
Set DPD No. 1 HR/No. 3 HR 0.1 - 10 mg/L Cl2 a) DPD ciascuna 250 517792BT
DPD No.3 HR Evo 0.1 - 10 mg/L Cl2 a) DPD Pastiglia / 100 511920BT
DPD No. 3 HR Evo 0.1 - 10 mg/L Cl2 a) DPD Pastiglia / 250 511921BT
DPD No. 3 HR Evo 0.1 - 10 mg/L Cl2 a) DPD Pastiglia / 500 511922BT
Cloro libero DPD F10 0.02 - 2 mg/L Cl2 a) DPD Polvere / 100 pz. 530100
Cloro libero DPD F10 0.02 - 2 mg/L Cl2 a) DPD Polvere / 1000 pz. 530103
Cloro totale DPD F10 0.02 - 2 mg/L Cl2 a) DPD Polvere / 100 pz. 530120
Cloro totale DPD F10 0.02 - 2 mg/L Cl2 a) DPD Polvere / 1000 pz. 530123
Titolo Online Download Type Format Versione lingua Download diretto
Scheda tecnica 280102 - MD50 Cloro, reagenti liquidi Scheda tecnica PDF (0.20 MB)
The new MD50 Single Parameter-Photometer Leaflets PDF (1.83 MB)
Istruzioni d‘uso Singolo metodo M100 - Cloro T Procedura Metodo singolo PDF (3.49 MB)
Istruzioni d‘uso Singolo metodo M101 - Cloro L Procedura Metodo singolo PDF (3.49 MB)
Istruzioni d‘uso Singolo metodo M103 - Cloro HR T Procedura Metodo singolo PDF (3.49 MB)
Istruzioni d‘uso Singolo metodo M110 - Cloro PP Procedura Metodo singolo PDF (2.54 MB)
Validation Data DPD No.1 Free Chlorine Validation Data PDF (0.12 MB)
Validation Data Free Chlorine DPD F10 Validation Data PDF (0.12 MB)
Validation Data Total Chlorine DPD F10 Validation Data PDF (0.12 MB)
  • 1 Instrument in Carrying case
  • 2 batteries (AA)
  • 3 round cuvettes (glass) with lid and Sealing rings
  • 1 Screwdriver
  • 3 Stirring rods
  • 1 Syringe 10 mL
  • 1 Cleaning brush
  • 1 USB-C to USB-A cable
  • 1 Instruction manual
  • 1 Certificate (COC)
  • 1 Warranty information
Titolo SDS Country Download diretto
Chlorine Free - DPD F10_PD 250
Chlorine Total - DPD F10_PD250
DPD 1 Buffer solution
DPD 1 Reagent Solution
DPD 3 Reagent Solution
DPD No. 1
DPD No. 1 HR
DPD No. 1 High Calcium
DPD No. 3 EVO
DPD No. 3 HR
DPD No. 3 HR EVO
DPD No. 3 High Calcium
DPD No. 3 from Lot Code YA1E0132
DPD No. 4 EVO
DPD No. 4 from Lot Code YA2A0227