MD50 Chloor, vloeibare reagentia
Precise water control with proven and compact measuring system
- High-precision optics to ensure accuracy and reproducibility
- Wired and wireless data transfer option
- Multiple single parameter variants for diverse applications
The MD50 series offers a comprehensive range of single parameter photometers that meet the most diverse needs of water treatment. With its language-free user interface based on icons and animations, it offers unparalleled ease of use. The robust design of the MD50 ensures that the instrument can withstand the toughest conditions in the field.
Bestelnr. 280102
Toepassingen
- Afvalwaterzuivering
- Behandeling drinkwater
- Controle desinfecteermiddel
- Controle zwembadwater
- Ketelwater
- Koelwater
- Zuivering vervuild water
Productinformatie
The MD50 has several key features that make it a favorite among users.
Robust Design
The MD50 is built to last. Its rugged industrial design, complete with rubber-protected sides and an IP67 rating, ensures unmatched durability and reliability even in demanding environments.
Accurate, Reproducible Results
The innovative optical system of the MD50 delivers exceptional accuracy and speed, ensuring precise readings in record time.
Factory Programmed Methods
All MD50 instruments come with pre-programmed methods for different types of reagents. Simply select the test you need, prepare your sample, and test! To simplify test selection, you can choose the reagent type from the settings and display only your desired methods in the methods list.
User Calibration and User defined Method
A one-point calibration is possible with the MD50. The instrument automatically saves the calibration protocol in the logs along with the calibration factor. All user-calibrated methods are displayed with a calibration icon on the screen. Can't find the method you need? The MD50 also allows you to program a user-defined method using PC software.
One-Time-Zero Function
Save time by zeroing the instrument once for each sample. When testing a new sample, zero the instrument once and all subsequent tests of that sample do not require re-zeroing. You can also activate or deactivate the OTZ function for all methods in the settings.
Automatic Data Storage
The MD50 automatically stores the last 100 readings and protocols with a time and date stamp. Results remain in storage even during a battery exchange.
Data Transfer
The MD50 offers smooth and effortless data transfer. You can transfer data to the AquaLX® app via NFC or use a USB cable to transfer data to PC software. Data can also be exported in CSV format for programs like Excel.
Ergonomic Design
Whether you're using the MD50 in the field or in the lab, its design makes it easy to handle and view the display. In the field, the compact size and side protections ensure a firm grip during use. In the lab, rubber feet on the bottom of the housing eliminate the need for two-handed operation or chasing your instrument around the workbench.
GLP Compliance
To ensure data quality and integrity, the MD50 creates and saves a protocol for each change made during operation.
2-year Warranty
Robust Design
The MD50 is built to last. Its rugged industrial design, complete with rubber-protected sides and an IP67 rating, ensures unmatched durability and reliability even in demanding environments.
Accurate, Reproducible Results
The innovative optical system of the MD50 delivers exceptional accuracy and speed, ensuring precise readings in record time.
Factory Programmed Methods
All MD50 instruments come with pre-programmed methods for different types of reagents. Simply select the test you need, prepare your sample, and test! To simplify test selection, you can choose the reagent type from the settings and display only your desired methods in the methods list.
User Calibration and User defined Method
A one-point calibration is possible with the MD50. The instrument automatically saves the calibration protocol in the logs along with the calibration factor. All user-calibrated methods are displayed with a calibration icon on the screen. Can't find the method you need? The MD50 also allows you to program a user-defined method using PC software.
One-Time-Zero Function
Save time by zeroing the instrument once for each sample. When testing a new sample, zero the instrument once and all subsequent tests of that sample do not require re-zeroing. You can also activate or deactivate the OTZ function for all methods in the settings.
Automatic Data Storage
The MD50 automatically stores the last 100 readings and protocols with a time and date stamp. Results remain in storage even during a battery exchange.
Data Transfer
The MD50 offers smooth and effortless data transfer. You can transfer data to the AquaLX® app via NFC or use a USB cable to transfer data to PC software. Data can also be exported in CSV format for programs like Excel.
Ergonomic Design
Whether you're using the MD50 in the field or in the lab, its design makes it easy to handle and view the display. In the field, the compact size and side protections ensure a firm grip during use. In the lab, rubber feet on the bottom of the housing eliminate the need for two-handed operation or chasing your instrument around the workbench.
GLP Compliance
To ensure data quality and integrity, the MD50 creates and saves a protocol for each change made during operation.
2-year Warranty
Optiek | LED, spectrometersensor, interferentiefilter (alleen geselecteerde varianten) |
Lichtbron | LED |
Wellenlänge | 530 |
Fotometrisch bereik | 0 - 3 Abs |
Geschikte cuvetten | Ronde cuvetten 24 mm |
Display | Lcd met achtergrondverlichting |
Interfaces | USB-C NFC (Near Field Communication) |
Data transfer formaat | .csv |
Bediening | Folietoetsenbord |
Auto – OFF | Ja |
Programmeerbaarheid | ja met pc-software |
IJking | Fabrieks- en gebruikersafstelling - terugkeer naar fabrieksafstelling op elk moment mogelijk |
Updates | Firmware en methoden bijwerken |
intern geheugen | Внутренняя кольцевая память на 100 записей данных |
Levensduur batterij | ca. 5000 metingen (zonder achtergrondverlichting) |
Draagbaarheid | Draagbaar |
Mate van vervuiling | 2 |
Maximale hoogte boven zeeniveau | 3500 m |
Bedrijfsomstandigheden | 5 - 50 °C при относительной влажности 30 - 95 % (без конденсации) |
Beschermingsklasse | IP 67 |
Compliance | CE |
Talen gebruiksaanwijzing | Duits, Engels, Frans, Spaans, Italiaans, Portugees, Chinees, Nederlands |
Afmetingen | 155 x 76 x 45 mm |
Testparameter | Meetbereik | Nummer methode | Chemische methode |
---|---|---|---|
Chloor HR T | 0.1 - 10 mg/L Cl2 | M103 | DPD |
Chloor L | 0.02 - 4.0 mg/L Cl2 | M101 | DPD |
Chloor PP | 0.02 - 2 mg/L Cl2 | M110 | DPD |
Chloor T | 0.01 - 6.0 mg/L Cl2 | M100 | DPD |
Omschrijving | Meetbereik | Chemische methode | Verpakkingseenheid | Bestelnr. | Offertewagen |
---|---|---|---|---|---|
DPD Nr.1 | 0.01 - 6.0 mg/L Cl2 a) | DPD | Tablet / 100 | 511050BT |
|
DPD Nr. 1 | 0.01 - 6.0 mg/L Cl2 a) | DPD | Tablet / 250 | 511051BT |
|
DPD Nr. 1 | 0.01 - 6.0 mg/L Cl2 a) | DPD | Tablet / 500 | 511052BT |
|
DPD Nr. 3 | 0.01 - 6.0 mg/L Cl2 a) | DPD | Tablet / 100 | 511080BT |
|
DPD Nr. 3 | 0.01 - 6.0 mg/L Cl2 a) | DPD | Tablet / 250 | 511081BT |
|
DPD Nr. 3 | 0.01 - 6.0 mg/L Cl2 a) | DPD | Tablet / 500 | 511082BT |
|
DPD Nr. 1 hoog calcium | 0.01 - 6.0 mg/L Cl2 a) | DPD | Tablet / 100 | 515740BT |
|
DPD Nr. 1 hoog calcium | 0.01 - 6.0 mg/L Cl2 a) | DPD | Tablet / 250 | 515741BT |
|
DPD Nr. 1 hoog calcium | 0.01 - 6.0 mg/L Cl2 a) | DPD | Tablet / 500 | 515742BT |
|
DPD Nr. 3 hoog calcium | 0.01 - 6.0 mg/L Cl2 a) | DPD | Tablet / 100 | 515730BT |
|
DPD Nr. 3 hoog calcium | 0.01 - 6.0 mg/L Cl2 a) | DPD | Tablet / 250 | 515731BT |
|
DPD Nr. 3 hoog calcium | 0.01 - 6.0 mg/L Cl2 a) | DPD | Tablet / 500 | 515732BT |
|
DPD Nr. 4 | 0.01 - 6.0 mg/L Cl2 a) | DPD | Tablet / 100 | 511220BT |
|
DPD Nr. 4 | 0.01 - 6.0 mg/L Cl2 a) | DPD | Tablet / 250 | 511221BT |
|
DPD Nr. 4 | 0.01 - 6.0 mg/L Cl2 a) | DPD | Tablet / 500 | 511222BT |
|
DPD No. 3 Evo | 0.01 - 6.0 mg/L Cl2 a) | DPD | Tablet / 100 | 511420BT |
|
DPD No. 3 Evo | 0.01 - 6.0 mg/L Cl2 a) | DPD | Tablet / 250 | 511421BT |
|
DPD No. 3 Evo | 0.01 - 6.0 mg/L Cl2 a) | DPD | Tablet / 500 | 511422BT |
|
DPD Nr.4 Evo | 0.01 - 6.0 mg/L Cl2 a) | DPD | Tablet / 100 | 511970BT |
|
DPD Nr. 4 Evo | 0.01 - 6.0 mg/L Cl2 a) | DPD | Tablet / 250 | 511971BT |
|
DPD Nr. 4 Evo | 0.01 - 6.0 mg/L Cl2 a) | DPD | Tablet / 500 | 511972BT |
|
DPD 1 bufferoplossing, blauw flesje | 0.02 - 4.0 mg/L Cl2 a) | DPD | 15 mL | 471010 |
|
DPD 1-bufferoplossing | 0.02 - 4.0 mg/L Cl2 a) | DPD | 100 mL | 471011 |
|
DPD 1 bufferoplossing in verpakking van 6 stuks | 0.02 - 4.0 mg/L Cl2 a) | DPD | 1 St. | 471016 |
|
DPD 1 reagensoplossing, groen flesje | 0.02 - 4.0 mg/L Cl2 a) | DPD | 15 mL | 471020 |
|
DPD 1-reagensoplossing | 0.02 - 4.0 mg/L Cl2 a) | DPD | 100 mL | 471021 |
|
DPD 1 reagensoplossing in verpakking van 6 stuks | 0.02 - 4.0 mg/L Cl2 a) | DPD | 1 St. | 471026 |
|
DPD 3 oplossing, rood flesje | 0.02 - 4.0 mg/L Cl2 a) | DPD | 15 mL | 471030 |
|
DPD 3 oplossing | 0.02 - 4.0 mg/L Cl2 a) | DPD | 100 mL | 471031 |
|
DPD 3 oplossing in verpakking van 6 stuks | 0.02 - 4.0 mg/L Cl2 a) | DPD | 1 St. | 471036 |
|
DPD reagentia set | 0.02 - 4.0 mg/L Cl2 a) | DPD | 1 St. | 471056 |
|
DPD Nr. 1 HR | 0.1 - 10 mg/L Cl2 a) | DPD | Tablet / 100 | 511500BT |
|
DPD Nr. 1 HR | 0.1 - 10 mg/L Cl2 a) | DPD | Tablet / 250 | 511501BT |
|
DPD Nr. 1 HR | 0.1 - 10 mg/L Cl2 a) | DPD | Tablet / 500 | 511502BT |
|
DPD Nr. 3 HR | 0.1 - 10 mg/L Cl2 a) | DPD | Tablet / 100 | 511590BT |
|
DPD Nr. 3 HR | 0.1 - 10 mg/L Cl2 a) | DPD | Tablet / 250 | 511591BT |
|
DPD Nr. 3 HR | 0.1 - 10 mg/L Cl2 a) | DPD | Tablet / 500 | 511592BT |
|
Set DPD nr. 1 HR/nr. 3 HR | 0.1 - 10 mg/L Cl2 a) | DPD | per 100 | 517791BT |
|
Set DPD nr. 1 HR/nr. 3 HR | 0.1 - 10 mg/L Cl2 a) | DPD | per 250 | 517792BT |
|
DPD Nr.3 HR Evo | 0.1 - 10 mg/L Cl2 a) | DPD | Tablet / 100 | 511920BT |
|
DPD Nr. 3 HR Evo | 0.1 - 10 mg/L Cl2 a) | DPD | Tablet / 250 | 511921BT |
|
DPD Nr. 3 HR Evo | 0.1 - 10 mg/L Cl2 a) | DPD | Tablet / 500 | 511922BT |
|
Chloor vrij DPD F10 | 0.02 - 2 mg/L Cl2 a) | DPD | Poeder / 100 St. | 530100 |
|
Chloor vrij DPD F10 | 0.02 - 2 mg/L Cl2 a) | DPD | Poeder / 1000 St. | 530103 |
|
Chloor totaal DPD F10 | 0.02 - 2 mg/L Cl2 a) | DPD | Poeder / 100 St. | 530120 |
|
Chloor totaal DPD F10 | 0.02 - 2 mg/L Cl2 a) | DPD | Poeder / 1000 St. | 530123 |
|
- 1 Instrument in Carrying case
- 2 batteries (AA)
- 3 round cuvettes (glass) with lid and Sealing rings
- 1 Screwdriver
- 3 Stirring rods
- 1 Syringe 10 mL
- 1 Cleaning brush
- 1 USB-C to USB-A cable
- 1 Instruction manual
- 1 Certificate (COC)
- 1 Warranty information