MD50 Хлор HR (йодистый калий)
Precise water control with proven and compact measuring system
- High-precision optics to ensure accuracy and reproducibility
- Wired and wireless data transfer option
- Multiple single parameter variants for diverse applications
The MD50 series offers a comprehensive range of single parameter photometers that meet the most diverse needs of water treatment. With its language-free user interface based on icons and animations, it offers unparalleled ease of use. The robust design of the MD50 ensures that the instrument can withstand the toughest conditions in the field.
Номер заказа 280140
Области применения
- Контроль дезинфицирующих средств
- Котельная вода
- Обработка сточных вод
- Обработка сырой воды
- Охлаждающая вода
Информация о продукте
The MD50 has several key features that make it a favorite among users.
Robust Design
The MD50 is built to last. Its rugged industrial design, complete with rubber-protected sides and an IP67 rating, ensures unmatched durability and reliability even in demanding environments.
Accurate, Reproducible Results
The innovative optical system of the MD50 delivers exceptional accuracy and speed, ensuring precise readings in record time.
Factory Programmed Methods
All MD50 instruments come with pre-programmed methods for different types of reagents. Simply select the test you need, prepare your sample, and test! To simplify test selection, you can choose the reagent type from the settings and display only your desired methods in the methods list.
User Calibration and User defined Method
A one-point calibration is possible with the MD50. The instrument automatically saves the calibration protocol in the logs along with the calibration factor. All user-calibrated methods are displayed with a calibration icon on the screen. Can't find the method you need? The MD50 also allows you to program a user-defined method using PC software.
One-Time-Zero Function
Save time by zeroing the instrument once for each sample. When testing a new sample, zero the instrument once and all subsequent tests of that sample do not require re-zeroing. You can also activate or deactivate the OTZ function for all methods in the settings.
Automatic Data Storage
The MD50 automatically stores the last 100 readings and protocols with a time and date stamp. Results remain in storage even during a battery exchange.
Data Transfer
The MD50 offers smooth and effortless data transfer. You can transfer data to the AquaLX® app via NFC or use a USB cable to transfer data to PC software. Data can also be exported in CSV format for programs like Excel.
Ergonomic Design
Whether you're using the MD50 in the field or in the lab, its design makes it easy to handle and view the display. In the field, the compact size and side protections ensure a firm grip during use. In the lab, rubber feet on the bottom of the housing eliminate the need for two-handed operation or chasing your instrument around the workbench.
GLP Compliance
To ensure data quality and integrity, the MD50 creates and saves a protocol for each change made during operation.
2-year Warranty
Robust Design
The MD50 is built to last. Its rugged industrial design, complete with rubber-protected sides and an IP67 rating, ensures unmatched durability and reliability even in demanding environments.
Accurate, Reproducible Results
The innovative optical system of the MD50 delivers exceptional accuracy and speed, ensuring precise readings in record time.
Factory Programmed Methods
All MD50 instruments come with pre-programmed methods for different types of reagents. Simply select the test you need, prepare your sample, and test! To simplify test selection, you can choose the reagent type from the settings and display only your desired methods in the methods list.
User Calibration and User defined Method
A one-point calibration is possible with the MD50. The instrument automatically saves the calibration protocol in the logs along with the calibration factor. All user-calibrated methods are displayed with a calibration icon on the screen. Can't find the method you need? The MD50 also allows you to program a user-defined method using PC software.
One-Time-Zero Function
Save time by zeroing the instrument once for each sample. When testing a new sample, zero the instrument once and all subsequent tests of that sample do not require re-zeroing. You can also activate or deactivate the OTZ function for all methods in the settings.
Automatic Data Storage
The MD50 automatically stores the last 100 readings and protocols with a time and date stamp. Results remain in storage even during a battery exchange.
Data Transfer
The MD50 offers smooth and effortless data transfer. You can transfer data to the AquaLX® app via NFC or use a USB cable to transfer data to PC software. Data can also be exported in CSV format for programs like Excel.
Ergonomic Design
Whether you're using the MD50 in the field or in the lab, its design makes it easy to handle and view the display. In the field, the compact size and side protections ensure a firm grip during use. In the lab, rubber feet on the bottom of the housing eliminate the need for two-handed operation or chasing your instrument around the workbench.
GLP Compliance
To ensure data quality and integrity, the MD50 creates and saves a protocol for each change made during operation.
2-year Warranty
Оптика | Светодиод, датчик спектрометра, фильтр помех (только в некоторых вариантах) |
Источник света | LED |
Длина волны | Variant specific (415, 445, 480, 515, 530, 555, 590, 630, 680) |
Фотометрический диапазон | 0 - 3 Abs |
Подходящие кюветы | Круглые кюветы 13 мм Круглые кюветы 16 мм Круглые кюветы 24 мм |
Дисплей | ЖК-дисплей с подсветкой |
Интерфейсы | USB-C NFC (Near Field Communication) |
Формат передачи данных | .csv |
Обслуживание | Мембранная клавиатура |
Auto – OFF | Да |
Программируемость | да, с помощью программного обеспечения для ПК |
Юстировка | Заводская и пользовательская настройка - возврат к заводской настройке возможен в любое время |
Обновления | Обновление микропрограммного обеспечения и методов |
Встроенная память | Внутренняя кольцевая память на 100 записей данных |
Срок службы батареи | Приблизительно 5000 измерений (без подсветки) |
Переносимость | Портативный |
Степень загрязнения | 2 |
Максимальная высота над уровнем моря | 3500 m |
Окружающие условия | 5 - 50 °C при относительной влажности 30 - 95 % (без конденсации) |
Класс защиты | IP 67 |
Соответствие | CE |
Языки руководства по эксплуатации | Английский, Немецкий, Испанский, Французский, Португальский, Итальянский, Голландский, Турецкий, Русский, Китайский |
Размеры | 155 x 76 x 45 mm |
Параметр испытания | Диапазон измерений | Номер метода | Химический метод |
---|---|---|---|
Гипохлорит T | 0.2 - 16 % NaOCl | M212 | Йодид калия |
Хлор HR (KI) T | 5 - 200 mg/L Cl2 | M105 | KI / кислота |
Заголовок | Диапазон измерений | Химический метод | Упаковочная единица | Номер заказа | Котировочная таблица |
---|---|---|---|---|---|
хлорины HR (KI) | 5 - 200 mg/L Cl2 | KI / кислота | Таблетка / 100 | 513000BT |
|
хлорины HR (KI) | 5 - 200 mg/L Cl2 | KI / кислота | Таблетка / 250 | 513001BT |
|
Acidifying GP | 5 - 200 mg/L Cl2 | KI / кислота | Таблетка / 100 | 515480BT |
|
Acidifying GP | 5 - 200 mg/L Cl2 | KI / кислота | Таблетка / 250 | 515481BT |
|
Набор Хлорины HR (KI)/Acidifying GP | 5 - 200 mg/L Cl2 | KI / кислота | 100 каждая | 517721BT |
|
Набор Хлорины HR (KI)/Acidifying GP | 5 - 200 mg/L Cl2 | KI / кислота | 250 каждая | 517722BT |
|
хлорины HR (KI) | 5 - 200 mg/L Cl2 | KI / кислота | Таблетка / 100 | 501210 |
|
хлорины HR (KI) | 5 - 200 mg/L Cl2 | KI / кислота | Таблетка / 250 | 501211 |
|
Набор для разбавления гипохлорита натрия | 0.2 - 16 % NaOCl | Йодид калия | 1 Шт. | 414470 |
|
- 1 Инструмент в футляре для переноски
- 100 таблеток реагента Chlorine HR (KI)
- 100 таблеток реагента Acidifying GP
- 2 микробатареи (AA)
- 3 круглые (стеклянные) кюветы с крышками, Уплотнительные кольца
- 1 Отвертка
- 3 Палочка для перемешивания
- 1 Дозировочный шприц 10 mL
- 1 Щетка
- 1 Кабель USB-C - USB-A
- 1 Краткое руководство
- 1 Сертификат (соответствия)
- 1 Гарантийная декларация